Premier 412/816/832 Installation Manual
$/ Allow Engineer Programming
On: The
Access
code
programming menus.
Off: The Access code cannot access the Engineer
programming menus.
%/ Allow Test Call Transmission
On: The Access code can perform a test transmission to
the monitoring station (menu 92, see page 65).
Off: The Access code cannot perform a test transmission.
&/ Allow Alarm/Fault Acknowledgement
On: The Access code can be used to acknowledge and
reset alarms and service faults. A user with this option
can disarm the system after an alarm, even if the user
does not have the "Allow Disarming" option.
Off: The Access code cannot be used to acknowledge and
reset alarms and service faults.
'/ Allow User Programming
On: The Access code can access the user program menus
(menu 90 - 98).
Off: The Access code cannot access the user program
menus.
(/ Allow User Code Programming
On: The Access code can access users 01 to 31 in the
User programming menus (menus 80 - 85).
Off: The Access code cannot access user 01 to 31 in the
User programming menus.
)/ Local Partition Access Only
On: The Access code can only be used to arm and disarm
the partitions that are assigned to the remote keypad.
For example, if the user is assigned to all four
partitions and they use a remote keypad that is only
assigned to partition 1, they will only be permitted to
arm and disarm partition 1 at that particular remote
keypad.
Off: The Access code can be used at any remote keypad
(Global access).
User Text (LCD Only)
If the system is fitted with a LCD remote keypad you can
assign up to 8 characters of text to each user. This text is
used when viewing the system Event Log, see page 72.
User text is programmed in a similar way to mobile phones.
Characters are selected by pressing the corresponding key
the appropriate number of times (to select a character on
the same key, press + to move the cursor along). For
details on entering text, see page 21.
INS159-7
can
access
the
Engineer
)%
Programming the Control Panel

Program Standard Users

This menu option allows you to add "Standard" users to the
system. The user will automatically be assigned the
following options:
User Options 1: Partition 1 Access
Allow Arming
Allow Bypassing
Allow Disarming
Allow User Functions
User Options 2: Enable Open Reporting
Enable Close Reporting
Allow Global Bell/Sounder Silence
User Options 3: Allow Alarm/Fault Acknowledgement

Default ALL Users

This menu option allows you to default all Users to their
factory default settings. Before selecting this menu option
you MUST link out the "Load Defaults" pins (JP6) on the
control panel PCB, see page 7. After selecting this option,
User 01(Master) is reverted to 5678 and Users 02 onwards
are deleted.
)&
)'
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Premier 832Premier 816

Table of Contents