Using The Wood Burning Stove - RAIS GABO Instructions For Installation, Use And Maintenance Manual

Hide thumbs Also See for GABO:
Table of Contents

Advertisement

ENGLISH 
Using the wood burning stove 
Adjusting the air damper.    The damper has 3 settings. 
Control 
If the ash is white and the walls in the combustion chamber are soot free after the stove 
has been used, the air regulation was set correctly and the wood was sufficiently dry. 
RAIS ­ manual for Rais Gabo, Pina, Vola & Vola Soapstone 
Position 1 
The damper is closed meaning that there is no air 
intake. 
Position 2 
Push the lever until the first click. This position 
gives full secondary air. 
During normal use the lever is set between position 
1 and 2. 
When the flames are clear and yellow, the damper 
is set correctly, i.e. resulting in a slow/optimal 
burning. 
Position 3 
Pull the handle out, and push it to the right. 
The air damper is completely open and gives full 
primary and secondary air. This position is for the 
lighting stage and is not used under normal 
operation.