  • Page 1 Dansk RAIS - manual til RAIS 500 U S E R M A N U A L R A I S 5 0 0...
  • Page 2 ENVIRONMENTALLY FRIENDLY FIRE! 5 Eco friendly advices for sensible heating - Environmentally and moneywise common sense. 1). Effective lighting. Use dry brushwood, kindling or a few cross pages of newspapers. Open the air control (plenty of air for the burning), to ensure that the heated wood is burning rapidly.
  • Page 3: Table Of Contents

    English RAIS - manual for RAIS 500 Rais 500 Revision: Date 10 July 2012 INTRODUCTION ......................4 WARRANTY ........................4 SPECIFICATIONS ......................5 INSTALLATIONS INSTRUCTIONS..................6 CONVECTION .......................7 CHIMNEY ........................7-8 VENTILATION .........................9 CE-LABELLING ......................10 AIR-SYSTEM ........................11 INSTALLATION .......................12-13 INSTALLATION DISTANCE ..................14-21 FUEL ...........................22 REGULATION OF COMBUSTION AIR ................23 USING THE WOOD BURNING STOVE ................24...
  • Page 4: Introduction

    These appliances have been approved by HETAS Ltd as intermittent operating appliances for burning wood logs only. A RAIS wood burning stove is more than just a heat source: it also shows that you care about design and quality in your home.
  • Page 5: Specifications

    English RAIS - manual for RAIS 500 Specifications RAIS 500 Nominell output (kW): Min./Max. output(kW): Heating area (m ca. 60-120 Stove’s width/depth/height (mm): 708-550-474 Combustion champer’s width/depth/height (mm): 556-306-295 Recommended amount of wood when fuelling (kg): (Distributed on 2-3 logs of wood approx. 25 cm) Min.
  • Page 6: Installation Instructions

    English RAIS - manual for RAIS 500 Installation instructions The following pages give instructions for the safe and proper installation of this heating appliance in the UK. These instructions cover the basic principles of installation, although detail may need slight modification to suit particular local site conditions. In all cases the installation must comply with current UK Building Regulations, Local Authority Byelaws and other specifications or regulations as they affect the installation of the stove.
  • Page 7: Convection

    RAIS - manual for RAIS 500 Convection RAIS stoves are convection stoves. This means that the stove’s back and side panels are not over-heated. Convection means that there is a circulation of air, which ensures that the heat is distributed more evenly throughout the entire room. The cold air is sucked in at the base of the stove up through the convection channel, which runs along the stove’s...
  • Page 8 English RAIS - manual for RAIS 500 A single wall metal fluepipe is suitable for connecting the stove to the chimney but is not suitable for using for the complete chimney. The chimney and connecting fluepipe must have a minimum diameter of 150 mm and its dimension should be not less than the size of the outlet socket of the stove which is 150 mm in diameter.
  • Page 9: Ventilation

    English RAIS - manual for RAIS 500 Ventilation - make the best possible use of the inserts. The stove is equipped with four convection air outlet, which may be connected with suit- able air ducts to other rooms.
  • Page 10: Ce-Labelling

    Raumheizer für feste Brennstoffe EC.NO: 511 Appliance fired by wood Poêle pour combustibles solides RAIS 500 1G / 1SG / 2G / 2SG / 3G / 3SG Anordningen må kun installeres i forbindelse med ubrændbart materiale. AFSTAND TIL BRÆNDBART, BAGVÆG DK: SE BRUGERVEJLEDNING...
  • Page 11: Air-System

    English RAIS - manual for RAIS 500 Air-system When mounting the Air system ensures that the air control system get fresh air from outside.ra. To ensure that Air system works, you have to build in items of ensuring that heres can be no vacuum in the home.
  • Page 12: Installation

    When you choose where to set up your RAIS wood burning stove, you should consider the heat distribution to the other rooms. This will enable you to get the best use out of your stove.
  • Page 13 RAIS - manual for RAIS 500 Lift the stove from the pallet to the place of installation on a suitable floor protection. The stove can be mounted with rack and adjustable leg (buy accessories at your local RAIS dealer) The stove is aligned by adjusting screws, so the lower edge of the glass door is in horizon- tal position and the surface of the door is vertical when the door is closed.
  • Page 14 English RAIS - manual for RAIS 500 Mounting distance - (height x width) 474 x 732 A wood burner insert should never fit tightly. Steel expands when heated. Panel wall Brick wall...
  • Page 15 English RAIS - manual for RAIS 500 Mounting distance 2G - (height x width) 474 x 708 A wood burner insert should never fit tightly. Steel expands when heated. Panel wall Brick wall...
  • Page 16 English RAIS - manual for RAIS 500 Mounting distance 3G - (height x width) 474 x 708 A wood burner insert should never fit tightly. Steel expands when heated. Panel wall Brick wall...
  • Page 17 English RAIS - manual for RAIS 500 Mounting distance for panelled wall - non-combustible material To guide the hot air out of the gratings, we recommends to install a non-flammable plate just above the holes. NB!! Recommended min convection Insulated chimney down to the area above the stove : 800 cm²...
  • Page 18 English RAIS - manual for RAIS 500 Mounting distance for brick wall / firewall Recommended min convection To guide the hot air out of the area above the stove : 800 cm² gratings, we recommends to (may be distributed) install a non-flammable plate just above the holes.
  • Page 19 English RAIS - manual for RAIS 500 Mounting distance - 2G / 3G non-combustible material: Recommended min convection area above the stove : 800 cm² (may be distributed) NB!! To guide the hot air out of the Insulated chimney down...
  • Page 20 English RAIS - manual for RAIS 500 Mounting distance - 2G / 3G brick: If not generating enough convection, there may be damage to the brick walls. To guide the hot air out of the gratings, we recommends to Recommended min convection install a non-flammable plate area above the stove : 800 cm²...
  • Page 21: Installation Distance In Case Of Combustible Wall

    English RAIS - manual for RAIS 500 Installation distance in case of combustible wall To find out whether the wall next to where the stove is going to be installed is flammable, you should contact your building contractor or the local building authorities.
  • Page 22: Fuel

    English RAIS - manual for RAIS 500 Operating instructions Please note that HETAS Ltd Appliance Approval only covers the use of dry sea- soned wood logs on this appliance. HETAS Ltd Approval does not cover the use of other fuels either alone or mixed with the wood logs, nor does it cover instruc-...
  • Page 23: Regulation Of Combustion Air

    2-3 days before you need it. Regulating the combustion air All RAIS stoves are equipped with a one-handed operating lever for regulating the damp- er. The stove-specific regulating mechanisms can be seen on the diagrams. Primary air is the combustion air added to the primary combustion zone, i.e. the bed of glowing embers.
  • Page 24: Using The Wood Burning Stove

    English RAIS - manual for RAIS 500 Using the wood burning stove Adjustment of the air damper - the damper has 3 settings Position 1 The damper is almost closed meaning that there is a minimal air intake. Position 2 Pull the lever until first click.
  • Page 25: Control

    English RAIS - manual for RAIS 500 Control If the ash is white and the walls in the combustion chamber sott-free after the stove has been used, the air regulation was set correctly and the wood was sufficiently dry. First usage A careful start pays off.
  • Page 26: Lighting And Fuelling

    English RAIS - manual for RAIS 500 Lighting and fuelling TIPS before firing up: Open a door or window close to the wood burning stove. If there is a “storm” in the stove coming from the chimney, it is advisable to place a screwed-up piece of newspaper between the upper baffle plate and the chimney, set the paper on fire, and wait until you hear a “rumbling”...
  • Page 27 English RAIS - manual for RAIS 500...
  • Page 28: Cleaning And Care

    English RAIS - manual for RAIS 500 Cleaning and care During cleaning and care, the stove must be cold. Woodstoves should be serviced every summer so they are ready for the winter season. Grates, firebricks, baffles, rope seals should all be checked that they are in good condition, Chimney and flues should be swept at least once a year, some liner manufacturers require their to be swept twice a year.
  • Page 29: Cleaning Of The Flue Ways

    English RAIS - manual for RAIS 500 Cleaning af the flue ways Remove the baffle plate by pushing up on one side - so it comes off the track - and gently tilt the other side toward the combustion chamber.
  • Page 30: Interruption Of Operation

    - unclean smoke channels - leaky chimney - leakage between chimney and flue If your stove continues to malfunction, we recommend that you contact your RAIS dis- tributor or chimney sweep. IMPORTANT!! To ensure safe burning there must be clear yellow flames or clear embers at all times.
  • Page 31: Accessories And Spare Parts

    English RAIS - manual for RAIS 500 Accessories 5111790 - Air box 511480490 - Convection grades 511480890 - Convection grades...
  • Page 32: Spare Parts

    Spare parts All replaceable parts can be bought as spare parts from your RAIS distributor. If spare parts other than those recommended by RAIS are used, the warranty is voided. See the following spare parts diagrams for the individual products.
  • Page 33 English RAIS - manual for RAIS 500...
  • Page 34 English RAIS - manual for RAIS 500...
  • Page 35 English RAIS - manual for RAIS 500...
  • Page 36 RAIS A/S Industrivej 20 DK-9900 Frederikshavn www.rais.dk...