2. Selection of installation place
Select the firm place that will not influenced by vibration and can bear the weight of the unit
Select the place with easy drainage and place can perform outdoor unit pipe connecting.
Select the place far away from heat source, vapor source and direct sunshine to avoid the causing
of the trouble in operation parts and the deformation of the casing.
Select the place where the cool air or warm air can evenly spread to every corner of the room.
Select the place near power receptacle leaving sufficient space around the unit. (Referring to
installation diagram)
Avoid the following installation places
Place with oil fog splash and much vapor (e.g. mechanical plant and kitchen, etc.) to prevent heat
exchanger from performance lowering and plastic parts from corroding to damage.
Place may generate or keep corrosive gas (sulfur dioxide, etc.), flammable gas (diluent,gasoline, etc.)
to prevent heat exchanger from corroding, plastic parts from damage and flammable gas from causing
fire accident.Hospital, etc. places near the machine generates electromagnetic wave or high frequency
signal to prevent the mixed wave from causing wrong action of the control parts.
Place can be blown by the sea wind (coastal area) to prevent the casing and heat exchanger from
corroding.
(Indoor unit) please keep the spaces larger than the following dimension.
3. Installation space
600

Installation of indoor unit

Selection of installation place
Place where it is easy to route drainage pipe and outdoor piping.
Place away from heat source and with less direct sunlight.
Place where cool and warm air could be delivered evenly to every corner of the room.
Place near power supply socket. Leave enough space around the unit (refer to installation
Fixing of the unit
1.
Position of the wall hole
Wall hole should be decided according to installtion place and piping direction. (refer to installation
drawings)
2.
Making a wall hole
Drill a hole of 70mm dia. with a little slope towards outside.
Install piping hole cover and seal it with putty after installation.
Unit (mm)
1000
50
-178-
>a__WcU[S^ <[c >a`V[e[a`Wc
600
rawings).