AD-300 Networked Hardwired Lock User Guide
Most LED and beep indicators are configured using the HHD. See the Schlage Utility Software User
Guide for more information.
Schlage Button
Extended (Toggle) unlock
Software version indicator on power-up
Card presented and not read
Card presented and read
Access denied
Access granted, momentary unlock (motor runs)
Relock (motor runs)
Credential key press
RS-485 address was set successfully
Not receiving communication from the ACP
1 X = major software version number. Y = minor software version number. Any number is possible.
ÎLosing power does not affect any programmed data. Use the HHD to configure power failure mode.
The default power failure mode is "as-is". When power failure is detected, the lock will instantly
switch to the configured mode. Credentials will no longer allow access. If the power failure mode is
"fail locked", then the mechanical override key must be used to gain access (when equipped).
Power Failure Modes
Mode
Fail As-Is (default)
Fail Unlocked
Fail Locked
For troubleshooting, browse to www.schlage.com/support.
LED AND BEEP REFERENCE
Action
POWER FAILURE
Lock remains in current state until power is restored.
Lock unlocks and remains unlocked until power is restored.
Lock locks and remains locked until power is restored.
TROUBLESHOOTING
2 Green
X Red, then Y Green
none
none
Controlled by ACP via PIB300
1 Green
1 Red
none
1 Green
Slow Flashing Red
Description
10
Lights
Beeps
1
0
0
0
1
0
1
1
1
4