P516-128 AD-300 AD-301 NETWORKED HARDWIRED LOCK USER GUIDE INSTRUCTIONS FOR ADAPTABLE SERIES NETWORKED HARDWIRED LOCKS Para el idioma español, navegue hacia www.schlage.com/support. Pour la portion française, veuillez consulter le site www.schlage.com/support.
The Schlage AD-300/AD-301 is an open architecture product designed to interface with Schlage brand access control panels (ACPs) as well as all other third party panels which use the Schlage RSI RS-485 protocol. When using a third party panel that does not use the Schlage RSI RS-485 protocol, the addition of a PIB300 is required to provide a Wiegand or Clock &...
The SUS is used for programming lock characteristics and setup only. Access rights for the AD-300/AD-301 are set by the access control panel, not by the SUS. For more information about the SUS, see AD-Series Locks in the SUS User Guide.
• Reset the lock to factory settings. See Reset to Factory Default Settings on page 10 for more information. • Wire an AD-300 lock to an access control panel (or to a PIB300 that is connected to an access control panel when using a third party panel that does not use the Schlage RSI RS-485 protocol).
RTX input on the lock main PCB during this procedure. 4. Press and release the Schlage button on the lock. Wait for the Schlage button to fl ash green. The lock address is now set to zero (0).
• In case of power outage, the lock will enter the confi gured power failure mode. See Power Failure on page 11 for more information. • The AD-300/AD-301 may be connected to external power using a UL294 listed Power Supply for UL installations, and a power supply that complies with CAN/UL-S318 or CAN/ULC-S319 for cUL installations.
Page 8
AD-300/AD-301 Networked Hardwired Lock User Guide 2 Wire (Half Duplex) 18 AWG, 1000 feet Power Supply max. run length VIN(PWR) UL 294 or ULC S319 Certified 250mA TDB+ @12 or 24 V DC RDB+ DO NOT attach power TDA- to A/B data terminals...
3. For locks with a card reader, present a credential to the reader. The lock will beep and the left side of the Schlage button will blink red one time. When the lock is in Factory Default mode and RS-485 is not connected, no credentials are accepted.
4. Press and release the inside push button (IPB) three (3) times within 10 seconds. One beep will sound and one red blink will occur with each press. 5. The Schlage button and IPB will both light green for one second and a one-second beep will sound to confi rm that the lock has been reset.
See the SUS User Guide for details on the confi guration of this setting. COMMUNICATION FAILURE If communication fails between the AD-300 /AD-301 and the ACP or the PIB300, the lock will go into communication failure mode. This mode can be confi gured using the SUS. See the SUS User Guide for more information.
None RS-485 address was set successfully 1 Green Communication from the ACP is not received by lock Slow Flashing Red Note: The access control panel may have some control over the Schlage button lights, and the actual response may vary.
Check that the wired power is connected The wired power may be correctly. improperly connected. Refer to the installation instructions that came with the AD-300/AD-301 lock, or this user guide for details on the above mentioned procedures. The AD-300/AD-301 The Wireless Check that the Wireless Communication...
AD-300/AD-301 Networked Hardwired Lock User Guide FCC STATEMENTS Ingersoll Rand Agency Statements Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2.
Page 15
AD-300/AD-301 Networked Hardwired Lock User Guide...