PARTS INSTALLATION
Part No.
Name of part
1
Installation plate
2
Mounting screw ST3.9x25 C
3
Clip anchor
Li uid side
Refrigerant
4
pipe
as side
5
Remote controller
Remote controller holder
8
NOTE A
A
C
The air conditioner can be connected only to a supply
with system impedance no more than 0.2 ohm. In case
necessary please consult your supply authority for system
impedance information.
C
e
o f
e r
n i
t s
l l a
t a
o i
, n
o
p
determine its location in a reception range.
• eep the remote controller at least 1 m apart from the
nearest T set or stereo e uipment.
• o not install the remote controller in a place exposed to
direct sunlight or close to a heating source, such as a stove.
• Note that the positive and negative poles are right positions
when loading batteries.

INSTALLATION PROCEDURE

INDOOR UNIT

• Place the installation guide pattern on the designated
installation place and mark the hole position.
• rill a hole and mount installation plate.
After determining the pipe
hole position drill the hole
at a slight downward slant
towards the outdoor side.
Note: When installing
the refrigerant pipes from
others side. A hole must
be place to allow fall
towards the outdoor unit.
ENGLISH
o
/
.35(18,000)
Parts
o
/
9.52(24000 30000)
you must
o
/
12. (18,000)
purchase
o
/
19.05(24000 30000)
Seal
rain elbow
e
a r
e t
h t
e
e r
m
o
e t
c
o
n
r t
l l o
5 mm
Outdoor
Indoor
ty
1
8
8
1
1
1
1
r e
o t
• Make mm 4 holes, in the wall at the four corners of mouting
plate (bracket) then insert appropriate mounting devices.
• Install the mounting plate using 4 pieces of mounting screw
securely at four corners and tighten the screw completely.
o not over tighten the screws and deform the back plate.
MODEL
120mm or
more to wall
Left re frigera nt
pipe hole
65
MODEL
Hooked Part
120mm or more
from the wall
130
CAUTIONS
e careful when handling the sharp edge of the mounting
plate.
W
• This indoor unit is ready for connection to the outdoor unit.
15cm or more
1
2
Mounting screw
ST2.9x10 C
Remote controller
holder
Remote controller
Air blowing
direction
Loop the
connective
cable.
150mm or mo re to c eiling
Installa tion plate
Indoor unit outline
70
70
920
( 16000Btu/h model)
150mm or more from the ceiling
1036
380
380
Indoor Unit Outline
C
120mm or
more to wall
Right r efrigerant
pipe hole
65
138
120mm or more
from the wall
130

Hide quick links: