York TLHA18-30OSAAAD Installation Manual page 12

Mini-split air conditioner
Table of Contents

Advertisement

W
Prepare the power source for exclusive with the air conditioner.
The supply voltage must comply with the rated voltage of the air conditioner: The plug socket shall be accessible after installation.
R
All the wiring must be based on the wiring nameplate which shown on the model.
CAUTIONS
• Perform the wiring with suf cient capacity. Installation places legally re uire a short circuit isolator to be attached to
prevent electrical shock.
o not extend the power cable code by cutting.
• Power voltage should in the range of 90
• The plug of the air conditioner takes a grounding leg, so clients should use a grounding socket so that the air conditioner
can be grounded ef ciently.
• If the power cord is damaged, replacement should be conducted by uali
N
Remark per EMC irective 89/33 /EEC
NOTE
To prevent icker impressions during the start of the compressor (technical process), following installation conditions do apply.
1. The power connection for the air conditioner has to be done at the main power distribution.
The distribution has to be of an low impedance, normally the re uired impedance reaches at a 32 A fusing point.
2. No other e uipment has to be connected with this power line.
3. For detailed installation acceptance, please refer to your contract with the power supplier if restrictions do apply for
products like washing machines, air conditioner or electrical ovens.
4. For power details of the air conditioner, refer to the rating plate of the product.
5. For any uestion contact your local dealer.
C
CAUTIONS
• Never modify the unit by removing any of the safety guards or by bypassing any of the safety interlock swithces.
• Connect the connecting cable correctly and connect the connecting cable to terminal as identi ed with their respective marks.
o not scratch the conductive core
surface of cables.
E
C
All electrical wiring and connections must comply with local codes and standards. Power supply cord and interconnection
cord used must not be lighter than Polychloroprene sheeted cord (245 IEC 5 or 05RN F).
isconnecting device must have a contact separation of at least 3 mm.
I
U
TLCA OSAAA D R
ENGLISH
110 of rated voltage.
inner insulator of power supply cables and do not deform or smash on the
ed technician or a serviceman.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tlca8-30osaaar

Table of Contents