PARTS INSTALLATION
Number
Name of Accessories
1
Installation plate
2
Clip anchor
3
Self-tapping screw AST3.9X25
4
Seal
Drain joint
5
Liquid side
Connecting
6
pipe
Assembly
Gas side
7
Remote contoroller
8
Self-tapping screw B ST3.9X10
9
Remote Controller holder
NOTES
Except the above parts provided, the other parts needed
during installation you must purchase.
CAUTIONS
• Ensure that the space around the left and right of the
indoor unit is more than 12cm.
The indoor unit should be installed allowing a minimum
clearance of 15cm from the ceiling.
• Use a stud
nder to locate studs to prevent unnecessary
damage to the wall.
• A minimum pipe run of 3 metres is required to minimise
vibration & excessive noise.
The indoor unit should be installed on the wall at a height
of 1.7 metres or more from the oor but less than 2.3
metres from the oor.
• Directions A, B and C should be free from obstructions.
NOTES
• This illustration is for explanation purposes only.
• Copper lines must be insulated independently.

INSTALLATION PROCEDURE

INDOOR UNIT
Fixing
• Place the installation guide pattern on the designated
installation place and mark the hole position.
• Drill a hole and mount installation plate.
• After determining the pipe
hole position. Drill the hole
at a slight downward slant
towards the outdoor side.
Note: When installing
the refrigerant pipes from
others side. A hole must
be place to allow fall
towards the outdoor unit.
10
ENGLISH
J440-EN.indd 10
Q'ty
1
8
8
1
1
ø 6.35 (7000-18000 Btu/h)
Parts you
must
ø 9.53 (7000-9000 Btu/h)
purchase
ø 12.7 (12000-18000 Btu/h)
1
2
1
ø 65 mm
Outdoor
Indoor
3
2
A
B
7
On/O
Auto
Mode
SET TEMP
Fan
Sleep
Swing
ON TIMER
Air Direction
Hr.
O
TIMER
Timer On
Hr.
Timer O
• Make 6 mm 4-6 holes, in the wall at the four corners of mount-
ing plate (bracket) then insert appropriate mounting devices.
• Install the mounting plate using 4-6 pieces of mounting screw
securely at four corners and tighten the screw completely.
Do not over tighten the screws and deform the back plate.
MODEL 09-18
150 mm or more to ceiling
Indoor unit outline
120 mm or
more to wall
Left refrigerant
70
pipe hole Ø65
A:780 (<16000Btu/h model), 920 (
1
6
Loop the
connective
cable.
C
Mounting screw B
ST3.9x10-C-H
9
8
Remote controller
holder
Installation plate
120 mm or
more to wall
Right refrigerant
pipe hole Ø65
70
f 16000Btu/h model)
2/14/08 1:26:41 PM