INSTALLATION MANUAL Mini-Split Air Conditioner TVHC09-18DSAAAR Read this manual before installation and operation Make sure that it is well kept for later reference Read this manual before installation and operation Make sure that it is well kept for later reference...
CONTENTS Safety precautions ..................3 Part names ....................4 Manual operation ..................5 How the air conditioner works ............6 Optimal operation ...................6 Adjusting air ow direction ..............7 Preparation before installation............8 Installation procedure ................10 Wiring Diagram ..................14 Please read this installation Air Purging ....................16 manual carefully before starting the installation.
PART NAMES INDOOR UNIT INDOOR UNIT 1. Front panel 2. Air inlet 3. Air lter 4. Air outlet 5. Horizontal air ow grille 6. Vertical air ow louver 7. Display panel 8. Remote controller OUTDOOR UNIT 9. Connecting pipe, drain hose 10.
HOW THE AIR CONDITIONER WORKS n AUTOMATIC OPERATION Press Sleep button • When you set the air conditioner in AUTO mode, it will automatically select cooling, heating (cooling/heating models only), or fan only operation depending on what temperature you have selected and the room temperature. Temperature •...
ADJUSTING AIR FLOW DIRECTION • Adjust the air flow direction properly, otherwise it might cause discomfort or cause uneven room temperatures. • Adjust the horizontal louver using the remote controller. • Adjust the vertical louver manually. Adjusting the Vertical Air Flow Direction (up - down) The air conditioner automatically adjusts the vertical air fl...
PREPARATION BEFORE INSTALLATION • Before doing any work, check the interior power supply cord and the main breaker capacity are su cient and the installation area is su cient and complies with the requirements. • Check that the power supply available agrees with nameplate voltage. •...
Page 9
OUTDOOR UNIT PICTURES TVHC09-18 Models 07-09 ENGLISH J440-EN.indd 9 2/14/08 1:26:40 PM...
PARTS INSTALLATION Q’ty Number Name of Accessories Installation plate Clip anchor Self-tapping screw AST3.9X25 Seal Drain joint ø 6.35 (7000-18000 Btu/h) Liquid side Connecting Parts you pipe must ø 9.53 (7000-9000 Btu/h) Assembly purchase Gas side ø 12.7 (12000-18000 Btu/h) Remote contoroller Self-tapping screw B ST3.9X10 Remote Controller holder...
Page 11
Wiring Piping • This indoor unit is ready for connection to the outdoor unit. The auxiliary piping can be connected in the directions shown the above diagram. To connect in the D , E and F direction, pipes will need to be extended. CAUTION •...
Indoor Unit Fixing • Thread the indoor unit piping and cable through the hole. • Hang the top of the unit onto the upper ridge of them in mounting plate. • Make sure that the unit is correctly hung in place by sliding it to the left, then to the right. •...
Page 13
To this effect, when the piping has been evacuated, close the pressure gauge tap, note the value on the gauge, then wait for 15 minutes. If the needle moves, there is a leak in the system. Make the necessary adjustments or repairs and repeat this procedure until the needle no longer moves.
Wiring Prepare the power source for exclusive with the air conditioner. The supply voltage must comply with the rated voltage of the air conditioner: The plug socket shall be accessible after installation. Remark: All the wiring must be based on the wiring nameplate which is shown on the model. CAUTIONS •...
Page 15
Outdoor Unit : TVHC12DSAAAR Indoor Unit : TVHC12DSAAAR OPTIONAL: FILTER CHOOSE ONE BY THE TRANSFORMER. ORANGE OPTIONAL: CAP ACITOR Outdoor Unit : TVHC18DSAAAR Indoor Unit : TVHC18DSAAAR OPTIONAL: CN16 CN15 CN14 YELLOW BLUE BROWN CN34 BLACK L N S GND CN32 BLUE CN31 CN33...
CAUTIONS After the con rmation of the above conditions, prepare the wiring as follows: 1) Never fail to have an individual power circuit speci cally for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. 2) The screw which fasten the wiring in the casing of electrical ttings are liable to come loose from vibrations to which the unit is subjected during the course of transportation.
Page 17
Electrical Work Input Rated Amp Power Cord Size (Switch/Fuse) a 12000Btu/h 10A/15A f 1.0/1.5mm 220-230V ~ 60Hz 220-240V ~ 50Hz f 12000Btu/h f 1.5mm NOTE: The supply voltage cannot be less than the rate voltage of the air conditioner. Defrosting operation (Available for heating only) 1.
MAINTENANCE WARNING It is necessary to stop the air conditioner and disconnect the power supply Household before cleaning. Drain Cleaner n Cleaning the indoor unit and remote controller CAUTIONS Thinner • Use a dry cloth to wipe the indoor unit and remote controller. •...
OPERATION TIPS The following events may occur during normal operation. 1. Protection of the air conditioner. Compressor protection • The compressor cannot restart for 3 minutes after it stops. Anti-cold air (Cooling and heating models only) • The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached.
TROUBLESHOOTING GUIDE A. The air conditioner does not 1. Power failure. 1. Wait for power resume. 2. Fuse blown or circuit breaker 2. Replace the fuse or reset the run. open. breaker. 3. Voltage is too low. 3. Find the cause and ? x it.
Page 21
INSTALLATION, REMOVAL AND DISPOSAL This product contains refrigerant under pressure, rotating parts, and electrical connections which may be a danger and cause in jury! All work must only be carried out by competent persons using suitable protective clothing and safety precautions. Read the Manual Risk of electric shock Unit is remotely controlled and...
Page 22
2008 Johnson Controls, Inc. www.johnsoncontrols.com Form No.035M000340-002 Johnson Controls reserve the right to change product features without prior notice.