To set the domestic hot water outlet temperature, access the operating menu, and using the button
parameter 2 – domestic hot water temperature. On pressing one of the buttons
and the domestic hot water outlet temperature setpoint will be displayed. Use the buttons
value. To activate the new value, press the button
the button
.
10,07 Outside temperature compensation
When the (optional) external probe is installed, the boiler regulation system functions in "Outside temperature
compensation" mode. In this mode, the temperature of the heating system is regulated according to the external
climatic conditions, so as to guarantee a high degree of comfort and energy saving all year round. Specifically, when
the external temperature falls, the central heating outlet temperature is increased, according to a pre-determined
"compensation curve".
In this mode, the temperature set in parameter 1 of the operating menu becomes the maximum central heatin g
outlet temperature. This should be set to Maximum to allow the system to regulate over the entire working range.
The boiler must be set during installation by qualified personnel. Other minor modifications can be made by the user
to improve the level of comfort: the compensation curve can in fact be modified by accessing the operating menu
with the button
and scrolling the menu, again using the button, to parameter 9.
The set compensation curve is displayed (refer to graph below). Pressing one of the buttons
to flash; use the buttons
the setting, do not press the
If the ambient temperature is lower than the required value, it is suggested to set a higher curve, and vice-versa.
Proceed with single unit increments or decreases, and check the results in the room.
Compensation curve
90
80
70
60
50
40
30
20
20
10.08 Maintenance
It is strongly recommended to effect the annual maintenance of the heating system and at least biennial checks of
the combustion device. Please refer to the "maintenance" section in this manual.
The casing, the control panel and the aesthetic parts of the boiler can be cleaned using a soft and damp cloth. Do
not use abrasives or solvents.
10.09 Anomalies
In the event of operating anomalies or problems, the display flashes and shows the code identifying the anomaly.
The anomalies marked by the letter "F" cause temporary shut-down, and are reset automatically as soon as the value
returns within the boiler's normal operating range.
The anomalies marked by the letter "A" cause a shut-down of the boiler which can be reset by the user. To reset
operation, press the
If the problem persists, or for any other anomalies, please refer to the "troubleshooting" chapter in this manual for
more details.
38
DOMINA 102 DGT
to set the required value. To activate the new curve, press the button
button, and press the button
10
(reset) button.
. To cancel the setting, do not press the button
.
10
9
0
External temperature °C
the display will start to flash
to set the required
the display starts
7
8
6
5
4
3
2
1
-10
-20
Fig. 38
display
, and press
. To cancel

Advertisement

Table of Contents
loading

This manual is also suitable for:

47-267-24

Table of Contents