Copper wall-mounted combination, gas fired boiler for central heating and domestic hot water production, fan assisted, room sealed compartment, electronic flame ignition and control
Table of Contents

Advertisement

3.03 Top Outlet Concentric Flue Connection
3.03.1 Vertical concentric connection
Concentric
Vertical
Connector
3.03.2 Horizontal concentric connection
A 90° bend (fig. 15) is supplied for the horizontal connection of air and flue gas pipes. This can be angled towards
the chosen wall in degrees of 45°.
Trim the 60 mm internal
diameter tube
Ø1=100 Ø2=60
14
DOMINA 102 DGT
A vertical connector can be supplied for vertical discharge
with concentric pipes.
The simple mounting and use of double lip gaskets at the
joints makes this an extremely easy and safe option.
25-30 mm
A=L+(85-90)mm
Fig. 15
Ø1
Ø2
L
Detail of mounting the bend
Fig. 14
60