HD Ultra-mini Bullet IR IP Camera
ICA-3110

Appendix A: I/O Configuration

1. I/O Connection
A. Please connect the G & DO pin to the external relay (buzzer) device.
When no event happens, DO output is 5V (DO and GND are disconnected). When the camera
detects event happening and triggers external alarm, DO output is 0V (DO and GND are
connected).
B. Please connect the G & DI pin to the external trigger device.
If you select "N.O" in "Input sensor setting", when external devise or circuit makes DI and GND
pin connected, the camera input alarm is triggered, and then camera will execute the action
user has set, for example, send snapshot to E-mail address.
If you select "N.C" in "Input sensor setting", when external devise or circuit makes DI and GND
pin disconnected, the camera input alarm is triggered, and then camera will execute the action
user has set, for example, send snapshot to E-mail address.
56