SERVICE MANUAL
HANDSFREE STAINLESS STEEL TELEPHONE
WITH OPTIONAL ADA FEATURE
EQUIPPED WITH SPK1.07r1 FIRMWARE
Communication Equipment
& Engineering Company
FOR
MODEL SSP-561-F
SSP-561-F-SPK1.07UNVLr1-ADA-ISSUE4.0
Serving the Telephone Industry Since 1930
519 W South Park Street
Okeechobee, FL 34972
Voice: 863-357-0798
Fax: 863-357-0006

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SSP-561-F and is the answer not in the manual?

Questions and answers

Summary of Contents for CEECO SSP-561-F

  • Page 1 SSP-561-F-SPK1.07UNVLr1-ADA-ISSUE4.0 SERVICE MANUAL MODEL SSP-561-F HANDSFREE STAINLESS STEEL TELEPHONE WITH OPTIONAL ADA FEATURE EQUIPPED WITH SPK1.07r1 FIRMWARE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street & Engineering Company Okeechobee, FL 34972 Voice: 863-357-0798 Fax: 863-357-0006...
  • Page 2: Important Information

    ISSUE 4.0 IMPORTANT INFORMATION CUSTOMER Please fill in before you continue. The following information is necessary when calling CEECO for assistance. MODEL NUMBER MODEL SSP-561-F WITH OPTIONAL ADA FEATURE, EQUIPPED WITH SPK1.07UNVLr1 FIRMWARE SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you, please have this information available when calling for technical support.
  • Page 3: Table Of Contents

    ....10 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS TESTING ..........................12 SPECIFICATIONS ......................13 PARTS LIST: ........................13 10.0 REPAIR AND RETURN INFORMATION ..........14 11.0 WARRANTY POLICY ....................15 12.0 DIAGRAM .......................... 16 CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 4: Introduction

    GENERAL The CEECO SSP-561-F is a sturdy, vandal resistant, hands free telephone, constructed with a heavy-gauge, stainless steel panel. Instead of a hookswitch and handset, the telephone has a Press to start/Press to stop button for initiation and termination of phone calls. Manual volume control is also provided inside the telephone.
  • Page 5: Programming

    Enter #00, followed by a series of ten (10) digits as selected from the following page. Location “00” is the telephone options location. By entering a selected number of 0-9 into each of the ten digit locations, the phone is customized for the particular installation. CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 6: Programming Continued

    Digit 8: 0 Always 0 for this model. Digit 9: Always 0 for this model. Digit 10: No Wink Detect 1-9 Length of the Wink (l = 50ms incremental to 450ms. 5 is recommended) CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 7: Programming Continued

    Allows 1-555-1212 information calls. #73 911 Allows 911 emergency calls. #74 1-800-***-**** Allows 1-800 calls. Etc. • Be sure to log your entries in the allowed call table on the next page for future reference. CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 8: Programming Continued

    #30 and the phone will Speed Dial - 1-800- 555-1212. • Be sure to log your entries in the speed dial table on the next page for future reference. CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 9: Programming Continued

    #68 _ - _ _ _ - _ _ _ - _ _ _ _ #49 _ - _ _ _ - _ _ _ - _ _ _ _ #69 _ - _ _ _ - _ _ _ - _ _ _ _ CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 10: Programming Continued

    If Digit 1 of Location #00 is set to "1", then there are no restrictions and any number may be dialed. RECOMMENDED TOOLS AND TEST EQUIPMENT Volt/Ohm Meter 5/16" Nut driver 3/8" Nut Driver Security Tool, CEECO Part Number 301-037 Flat Blade Screw Driver DTMF Test Set CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 11: Installation Notes And Assembly Instructions

    Run the inside station wire into the apparatus box/mounting location and terminate on the RJ11C modular jack inside, as depicted on the following page. This CEECO-provided jack must be used, as it contains required over-voltage protection. The use of a gas tube, or carbon station protector is recommended. The station ground should not exceed 50 ohms.
  • Page 12: Testing

    Reaction: The called party answers. A normal speakerphone conversation is allowed. Action: Finish the conversation. Press the "CALL" button, or wait until time out occurs. Reaction: The call is terminated. LED goes out. CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 13: Specifications

    QUANTITY PART NUMBER DESCRIPTION 406-019 Outer Cover Security Screw 301-018 Modular Line Cord 301-054 Modular Connector (RJ11C) 700-008 Keypad Cable 660-000 CEECO SPK Board 705-110 Connectorized Keypad 6020 Momentary Panel Switch 14123 Speaker 14067 Microphone 391-002 Stainless Steel Panel 361-01...
  • Page 14: Repair And Return Information

    10.3 NON-WARRANTY REPAIR CEECO will repair equipment out of warranty for a set charge plus parts. The customer must pay the shipping costs for both directions. 10.4 RETURN FOR CREDIT Material may be returned for credit only with prior approval. Material authorized for return is subject to a 20% restocking charge based on the manufacturer’s list price.
  • Page 15: Warranty Policy

    PRINTED CIRCUIT BOARDS Printed circuit boards should not be field repaired. If a unit is found to be faulty, replace it with another unit and return the faulty unit to CEECO for repair. Modifications by anyone other than CEECO will void the warranty.
  • Page 16: Diagram

    ON position BEFORE going off-hook. When programming is completed, move the mini jumpers to the OFF position. NOTE: Do not leave the mini jumpers in the ON position; this will decrease battery life. CEECO Communication Equipment & Engineering Company PROPRIETARY...
  • Page 17 ISSUE 4.0 CEECO Communication Equipment & Engineering Company PROPRIETARY...