Thick Facing Installation (stone, brick, or other non-combustible over 1" (25mm) thick)
If using a Fireplace Xtrordinair (FPX) arched face, see "Thick Facing with a Fireplace Xtrordinair Arched
Faces" on page 39.
Do not install masonry (or other
material) in front of the
fireplace. This area must remain
open to install the face.
TOP VIEW - Protruding Masonry
Fireplace
TOP VIEW - Recessed Masonry
Fireplace
NOTE: The nailing brackets are not used for this type
of installation - secure the fireplace to the floor with
the brackets along the base of the fireplace.
Travis Industries
Installation
Framing
Nailing Bracket
Drywall
Masonry
Framing
Drywall
(or cement board, etc.)
Masonry
(for qualified installers only)
Floor-Mounted Fireplaces or Raised Hearths:
Build the hearth 1" max (25mm) above the base
of the fireplace. The fireplace may be raised to
accommodate thicker hearth materials.
Raised Fireplaces:
Masonry is installed 1" (25mm)
(maximum) above the base of the
fireplace.
FRONT VIEW
4081126
36-1/4"
921mm
100-01210_000
29-1/4"
743mm
1"
25mm