13.
Combustion:
Measured in compliance with
Fuel
Output; min. - max.
Nominal output
Effi ciency
PM10 Dust emissions
Flue gas mass fl ow
Flue temperature
Chimney draught
Flue gas connection
Combustion air supply connection
(via the under side of the appliance!)
Convection air supply connection
(= connection for convection fans
(option))
Convection air outlet connection
Weight
Inside:
Dimensions
- surface area (b x d)
- clear fi re opening (h x b)
Interior panels
Bottom
Inner lining
Retardant plates (brake plates) (2x)
Outside:
Construction
Doors
62

TECHNICAL DATA

SLIDE BELL 55-55
EN 13229 : 2001 and EN 13229 - A2 : 2004
Wood
10 - 20 kW
15 kW
75%
3
57 mg/m
n
13.3 g/s
292°C
0.12 mbar
Ø180 mm (Ø178 mm exterior)
Ø125 mm (Ø123 mm exterior)
2 x
65 x 70 mm (= 91 cm
2 x Ø125 mm (≈ 245 cm
2
)
225 kg
0.62 x 0.36 = 0.22 m
2
450 x 570 mm
Vermiculite insulation plates 700 kg/m
Vermiculite insulation plates 700 kg/m
Steel (heat-resistant and rust-proof)
Vermiculite insulation plates 700 kg/m
Sheet-steel casing
Lift door
Door tilted forwards to allow window to be
cleaned
Instructions for use and installation instructions
English
2
)
2
, 1100°C
2
, 1100°C
2
, 1100°C

Advertisement