Rfid Errors - Monarch 9855 Application Notes

Hf (high frequency) rfid printer
Hide thumbs Also See for 9855:
Table of Contents

Advertisement

R F I D E r r o r s
052
Data type in the RFID Data Field must be 0 or 1. See "Defining the
RFID Data Field" for more information.
The starting block in the RFID Data Field is invalid. See "Defining
053
the RFID Data Field" for more information.
Rule Record Line xx. Upload device must be H (Host) for
226
Option 6.
228
Memory class identifier is invalid. The identifier must be A (AFI),
D (DSFID), or E (EAS) for Option 64. See "Using Option 64
(Program the AFI, DSFID, and EAS Fields)" for more information.
229
Byte code is invalid. Byte code must be an 8-bit (1 byte) character
for Option 64. See "Using Option 64 (Program the AFI, DSFID,
and EAS Fields)" for more information.
230
Lock code is invalid. Lock code must be 0 (Unlock) or 1 (Lock) for
Option 64. See "Using Option 64 (Program the AFI, DSFID, and
EAS Fields)" for more information.
Invalid data length/data mismatch. The data in the RFID Data
715
Field has an incorrect data length or there is a data type mismatch
between selected data type and actual data entered.
See "Defining the RFID Data Field" for more information on the
data length and for selecting the appropriate data type for the data
being entered. Check with your System Administrator about your
format.
740
Command, hardware, inventory, or memory allocation error.
There may be an RFID hardware or memory allocation error.
741
RFID tag missing. Tag not found in RF Field. The RFID tag was
not found in the RF Field (area inside the printer where RFID tag is
programmed.) Check supply loading. If you made supply or print
position settings, make sure the RFID tag was not moved out of
the programmable range. Refer to the HF Setup Guide & Supply
Chart for more information.
5-2 HF Application Notes