Power Source Error Code - Thermal Arc ARCMASTER 200 TS Service Manual

Inverter arc welder
Hide thumbs Also See for ARCMASTER 200 TS:
Table of Contents

Advertisement

10

POWER SOURCE ERROR CODE

Description
1 E01 error code displayed
Temperature sensor TH1
(protects IGBTs) is
greater than 80°C for
about 1 second.
2 E02 error code displayed
Temperature sensor TH2
(protects secondary
diodes) is greater than
80°C for about 1 second.
3 E03 error code displayed
Primary (input) current too
high.
4 E94 error code displayed
Temperature sensor TH1
for IGBTs or sensor TH2
for secondary diodes are
open circuit.
5 E99 error code displayed
Mains supply (input)
voltage has been turned
off but control circuit has
power from the primary
capacitors.
POWER SOURCE ERROR CODE
Possible Cause
A The Welding Power
Source's duty cycle has
been exceeded.
B Fan ceases to operate.
C Air flow is restricted by
vents being blocked.
A The Welding Power
Source's duty cycle has
been exceeded.
B Fan ceases to operate.
C Air flow is restricted by
vents being blocked.
A Primary current is too
high because welding arc
is too long.
B Mains supply voltage is
more than 10% below
nominal voltage.
The Welding Power
Source's temperature
sensors have
malfunctioned.
A Main on/off switch on
machine has been turned
off.
B Mains supply (input)
voltage has been turned
off.
Table 10-1: Power Source Error Codes
10 – 1
Remedy
A Let Power Source cool
down then keep within its
duty cycle.
B Have an Accredited
Thermal Arc Service Agent
investigate.
C Unblock vents then let
Power Source cool down.
A Let Power Source cool
down then keep within its
duty cycle.
B Have an Accredited
Thermal Arc Service Agent
investigate.tt
C Unblock vents then let
Power Source cool down.
A Reduce length of welding
arc.
B Have an Accredited
Thermal Arc Service Agent
or a qualified electrician
check for low Mains
voltage.
Have an Accredited
Thermal Arc Service Agent
check or replace the
temperature sensors.
A Turn on/off switch on.
B Have an Accredited
Thermal Arc Service Agent
or a qualified electrician
check the Mains voltage
and fuses.
Remarks
Weld current ceases.
Buzzer sounds
constantly.
Fan operates at max
speed.E01 resets when
TH1 decreases to 70°C
for about 30 seconds.
Weld current ceases.
Buzzer sounds
constantly.
Fan operates at max
speed.E02 resets when
TH2 decreases to 70°C
for about 30 seconds.
Weld current ceases.
Buzzer sounds
constantly.
Switch machine off then
on to reset E03 error.
Weld current ceases.
Buzzer sounds
constantly.
Switch machine off.
Weld current ceases.
Buzzer sounds
constantly.
Must switch machine off
then on to reset E99 error.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents