Kyocera ECOSYS M6026cidn Service Manual page 338

Hide thumbs Also See for ECOSYS M6026cidn:
Table of Contents

Advertisement

Connector
Pin
1
YC16
VDD5
2
Connected to
GND
Fax control
3
RESETN
PWB
4
VDD5_CUT
5
GND
6
WAKEUP
7
AUDIO
8
RESERVE
9
RESERVE
10
RESERVE
11
GND
12
RESERVE
13
RESERVE
14
GND
15
RESERVE
16
RESERVE
17
GND
18
USB_DP
19
USB_DN
20
VBUS
YC32
1
FEEDCL
Connected to
2
REVSOL
DP drive
3
PRESOLN
PWB
4
RELSOLN
5
DPDETN
6
OPSWN
7
ORGSWN
8
TIMSWN
9
GND
10
+3.3V2
11
GND
12
+24V2
13
MOTB2
14
MOTA2
15
MOTB1
16
MOTA1
Signal
I/O
O
3.3 V DC
-
-
I
0/3.3 V DC
O
3.3 V DC
-
-
O
0/3.3 V DC
I
Analog
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
I/O
-
I/O
-
O
3.3 V DC
O
0/24 V DC
O
0/24 V DC
O
0/24 V DC
O
0/24 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
-
-
O
3.3 V DC
-
-
O
24 V DC
O
0/24 V DC (pulse)
O
0/24 V DC (pulse)
O
0/24 V DC (pulse)
O
0/24 V DC (pulse)
Voltage
3.3 V DC power to FCPWB
Ground
Reset signal
3.3 V DC power to FCPWB
Ground
Control signal
Audio signal
-
-
-
Ground
-
-
Ground
-
-
Ground
USB data signal
USB data signal
3.3 V DC power to FCPWB
DPPFCL: On/Off
DPSBSOL: On/Off
DPPRSOL: On (Press)/Off
DPPRSOL: On (Release)/Off
DP set signal
DPOCS: On/Off
DPOS: On/Off
DPTS: On/Off
Ground
3.3 V DC power to DPDPWB
Ground
24 V DC power to PDPWB
DPPFM drive control signal
DPPFM drive control signal
DPPFM drive control signal
DPPFM drive control signal
2-3-15
2PX/2PY
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecosys m6526cidn6026