Kyocera ECOSYS M6026cidn Service Manual page 146

Hide thumbs Also See for ECOSYS M6026cidn:
Table of Contents

Advertisement

Code
Contents
1630
PF heater 2 low temperature
error (paper feeder 2)
An external temperature
higher than + 5C/+ 9F is not
detected when one minute
elapses after PF heater 2 is
turned on.
1800
Paper feeder communica-
tion error
Communication error between
engine PWB and optional
paper feeder.
2100
Developing motor error
The developing motor ready
input is not given for 5 s dur-
ing the main motor is ON.
Causes
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
PF heater 2 and PF heater PWB (YC2)
PF heater PWB (YC3) and PF main PWB
(YC113)
PF thermistor 2 and PF main PWB (YC115)
PF thermistor 2
Check the installation of the PF thermistor 2.
installed incor-
rectly.
Defective PF
Replace the side heater unit (Refer to the
thermistor 2.
service manual for the paper feeder).
Broken PF heater
Replace the side heater unit (Refer to the
2.
service manual for the paper feeder).
Defective PF
Replace the PF heater PWB or PF main
heater PWB or PF
PWB (Refer to the service manual for the
main PWB.
paper feeder).
Improper installa-
Follow installation instruction carefully again.
tion paper feeder.
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
PF main PWB (YC3) and engine PWB
(YC33)
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-27).
Defective PF main
Replace the PF main PWB (Refer to the ser-
PWB.
vice manual for the paper feeder).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Developing motor and engine PWB (YC14)
Defective drive
Check if the rollers and gears rotate
transmission sys-
smoothly. If not, grease the bushes and
tem of the develop-
gears. Check for broken gears and replace if
ing motor.
any.
Defective develop-
Replace the developing motor.
ing motor.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-27).
1-4-12