4700
VIDEO ASIC device error
5301
Broken cleaning lamp K
wire
When the cleaning lamp K is
driven, the lamp over-current
detection signal is detected
continuously for 10 times (1 s)
at 100 ms intervals.
5302
Broken cleaning lamp C
wire
When the cleaning lamp C is
driven, the lamp over-current
detection signal is detected
continuously for 10 times (1 s)
at 100 ms intervals.
5303
Broken cleaning lamp M
wire
When the cleaning lamp M is
driven, the lamp over-current
detection signal is detected
continuously for 10 times (1 s)
at 100 ms intervals.
Causes
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Main PWB (YC39) and relay PWB (YC3)
Relay PWB (YC2, 4) and engine PWB (YC8,
9)
Defective main
Replace the main PWB or the engine PWB
PWB or engine
and check for correct operation (see page 1-
PWB.
5-30, 1-5-27).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Drum unit K and Drum relay PWB (YC2)
Drum relay PWB (YC1) and engine PWB
(YC34)
Defective cleaning
Replace the drum unit K. (see page 1-5-21).
lamp K.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-27).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Drum unit C and Drum relay PWB (YC4)
Drum relay PWB (YC1) and engine PWB
(YC34)
Defective cleaning
Replace the drum unit C. (see page 1-5-21).
lamp C.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-27).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Drum unit M and Drum relay PWB (YC3)
Drum relay PWB (YC1) and engine PWB
(YC34)
Defective cleaning
Replace the drum unit M. (see page 1-5-21).
lamp M.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-27).
1-4-19