Parameter
Anti-dither
Sensor type
Record channel
Record Delay
Alarm out
Latch
Show message
Buzzer
Alarm upload
Send Email
Tour
PTZ Activation
5.8.3.2.2 Net Alarm
The network alarm interface is shown as in Figure 5-57.
Network alarm refers to the alarm signal from the network. System does not anti-dither
and sensor type setup. For setup information, please refer to chapter 5.8.3.2.1.
Function
whole week.
Click OK button, system goes back to local alarm
interface, please click save button to exit.
System only memorizes one event during the anti-dither
period. The value ranges from 5s to 600s.
There are two options: NO/NC.
System auto activates motion detection channel(s) to
record once an alarm occurs. Please note you need to set
alarm record period and go to Storage-> Schedule to set
current channel as schedule record.
System can delay the record for specified time after alarm
ended. The value ranges from 10s to 300s.
Enable alarm activation function. You need to select alarm
output port so that system can activate corresponding
alarm device when an alarm occurs.
System can delay the alarm output for specified time after
an alarm ended. The value ranges from 1s to 300s.
System can pop up a message to alarm you in the local
host screen if you enabled this function.
Check the box here to enable this function. The buzzer
beeps when an alarm occurs.
System can upload the alarm signal to the centre
(Including alarm centre).
If you enabled this function, System can send out an email
to alert you when an alarm occurs.
You need to check the box here to enable this function.
System begins 1-wiindow or multiple-window tour display
among the channel(s) you set to record when an alarm
occurs.
Here you can set PTZ movement when alarm occurs.
Such as go to preset X.