Focal Point L40 PINOIR- NG Installation & User's Instructions

Wall mounted high efficiency gas fire
Hide thumbs Also See for L40 PINOIR- NG:

Advertisement

INSTALLATION & USER INSTRUCTIONS
WALL MOUNTED HIGH EFFICIENCY GAS FIRE
Focal Point Fires plc.
Christchurch, Dorset BH23 2BT
Tel: 01202 499330
Fax: 01202 499326
www.focalpointfires.co.uk
e : sales@focalpointfires.co.uk
IN THE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEER TO INSTALL, REPAIR OR SERVICE THIS APPLIANCE
Please note : Except where otherwise stated, all rights, includ-
ing copyright in the text, images and layout of this booklet is
owned by Focal Point Fires plc. You are not permitted to copy
or adapt any of the content without the prior written permis-
sion of Focal Point Fires plc.
MODELS COVERED BY THESE INSTRUCTIONS
L40 PINOIR - NG
L40 PINOIR - LPG
L40 MEMOIR - NG
L40 MEMOIR - LPG
L40 REFLECTION - NG
L40 REFLECTION - LPG
L40 SATURN - NG
L40 SATURN - LPG
PINOIR
REFLECTION
The products covered by this booklet are protected under patent
All instructions must be handed to the user for safekeeping.
1
GB IE
F500183
F500430
F500361
F500431
F500049
F500432
BS EN 14829 : 2007
F500057
KM579167
F500433
MEMOIRS
GB2275331B.
Revision D - 11/11
©
2011 Focal Point Fires plc.
SATURN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the L40 PINOIR- NG and is the answer not in the manual?

Questions and answers

Summary of Contents for Focal Point L40 PINOIR- NG

  • Page 1 GB2275331B. owned by Focal Point Fires plc. You are not permitted to copy All instructions must be handed to the user for safekeeping. or adapt any of the content without the prior written permis- sion of Focal Point Fires plc.
  • Page 2: Table Of Contents

    • Consult ALL instructions before installation and use of this appliance. This appliance is free from any asbestos material. © © 2011 Focal Point Fires plc. 2011 Focal Point Fires plc.
  • Page 3: Appliance Data

    Clearance to the sides of the appliance are 100mm (4”) but curtains, drapes and other fabrics are not permitted within a distance of 500mm (20”) of the appliance sides. No such materials are permitted directly above the appliance regardless of distance. © 2011 Focal Point Fires plc.
  • Page 4: Ventilation

    QUANTITY DESCRIPTION Firebox and burner assembly Set of manufacturers instructions Decorative stone facia panel (Memoirs and Pinoir models) Decorative facia panel (Reflection and Saturn models) Screw and wall plug pack Rubber grommet Fitting template © 2011 Focal Point Fires plc.
  • Page 5: Gas Supply Routes

    Focal Point Fires plc. assumes absolutely no responsibility for injuries and/or damages that the force of earthquakes, vibra- may occur due to improper installation or handling. The appliance should not be installed tion and other external forces.
  • Page 6: Checking The Burner & Spark Gap

    • To turn to the PILOT position from the HIGH or LOW positions, press the control ‘HIGH’ position knob in, and return to the pilot position and release. • To turn the fire off, keep the knob pressed in, return to the OFF position and release. Figure 9 © 2011 Focal Point Fires plc.
  • Page 7: Operating Pressure

    Recommend that a guard be used for the protection of the young, pets, the elderly and the infirm. Advise the customer that the ventilation openings should not be blocked or obstructed in any way. © 2011 Focal Point Fires plc.
  • Page 8: Servicing

    To convert from parts per million (ppm) to a percentage (%) divide the ppm figure by 10,000. Examples : 35ppm = 0.0035%, 15ppm = 0.0015%, 5ppm = 0.0005%. Now divide the concentration of carbon monoxide (CO) expressed in © 2011 Focal Point Fires plc.
  • Page 9: Testing For Firebox Leakage

    • Leakage occurring. Carry out leakage test and rectify any problems. • Combustible materials used in incorrect positions. • Airborne substances such as cleaning materials/air fresheners are being drawn through the fire. • Other airborne contaminants such as dust, tobacco smoke, paint vapours. © 2011 Focal Point Fires plc.
  • Page 10 800mm (31.5”) measured from the top of the appliance glass panel. Combustible materials should not be positioned directly in front of the appliance within a distance of one metre. © 2011 Focal Point Fires plc.
  • Page 11 Test on a hidden part before cleaning. Clean only in the direction of the grain. GLASS PANEL - This can be cleaned with a suitable glass cleaner. Test on a small area first. PAINTED AREAS - These can be cleaned using a dry cloth. © 2011 Focal Point Fires plc.
  • Page 12 Contact details of Engineer As our policy is one of continuous improvement and development , we hope therefore you will understand we must retain the right to amend details and/or specifications without prior notice. © 2011 Focal Point Fires plc.