Focal Point L40 PINOIR - NG Installation & User's Instructions

Wall mounted high efficiency gas fire
Hide thumbs Also See for L40 PINOIR - NG:

Advertisement

Quick Links

INSTALLATION & USER INSTRUCTIONS
WALL MOUNTED HIGH EFFICIENCY GAS FIRE
Focal Point Fires plc.
Christchurch, Dorset BH23 2BT
Tel: 01202 499330
Fax: 01202 499326
www.focalpointfires.co.uk
e : sales@focalpointfires.co.uk
Questions or problems with your appliance?
Don't take it back to the store
01202 588601
just give us a call on
lines open between 9am and 5pm, Monday to Friday
IN THE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEER TO INSTALL, REPAIR OR SERVICE THIS APPLIANCE
Please note : Except where otherwise stated, all rights, includ-
ing copyright in the text, images and layout of this booklet is
owned by Focal Point Fires plc. You are not permitted to copy
or adapt any of the content without the prior written permis-
sion of Focal Point Fires plc.
MODELS COVERED BY THESE INSTRUCTIONS
L40 PINOIR - NG
L40 PINOIR - LPG
L40 MEMOIR - NG
L40 MEMOIR - LPG
L40 MERCANO - NG
L40 MERCANO - LPG
we're here to help
All instructions must be handed to the user for safekeeping.
1
MODEL SHOWN: MERCANO
The products covered by this booklet are protected under patent
GB2275331B.
Revision E - 03/13
GB IE
BS EN 14829 : 2007
KM579167
2013 Focal Point Fires plc.
'

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the L40 PINOIR - NG and is the answer not in the manual?

Questions and answers

Summary of Contents for Focal Point L40 PINOIR - NG

  • Page 1 GB2275331B. owned by Focal Point Fires plc. You are not permitted to copy All instructions must be handed to the user for safekeeping. or adapt any of the content without the prior written permis- sion of Focal Point Fires plc.
  • Page 2: Table Of Contents

    • As with any gas fire, a fire guard complying with BS 8423 must be used in presence of pets, children, and the elder- ly or infirm. • Consult ALL instructions before installation and use of this appliance. This appliance is free from any asbestos material. 2013 Focal Point Fires plc.
  • Page 3: Appliance Data

    Clearance to the sides of the appliance are 100mm (4”) but curtains, drapes and other fabrics are not permitted within a distance of 500mm (20”) of the appliance sides. No such materials are permitted directly above the appliance regardless of distance. 2013 Focal Point Fires plc.
  • Page 4: Ventilation

    QUANTITY DESCRIPTION Firebox and burner assembly Set of manufacturers instructions Decorative fascia Screw and wall plug pack Rubber grommet Fitting template Trim pack (Mercano only) Pair of left and right hand side panels (Mercano only) 2013 Focal Point Fires plc.
  • Page 5: Gas Supply Routes

    Focal Point Fires plc. assumes absolutely no responsibility for injuries and/or damages that the force of earthquakes, vibra- may occur due to improper installation or handling. The appliance should not be installed tion and other external forces.
  • Page 6: Testing And Commissioning

    • To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to the pilot position and release. • To turn the fire off, keep the knob pressed in, return to the OFF position and release. 2013 Focal Point Fires plc.
  • Page 7: Operating Pressure

    Ensure each screw is unscrewed approximately one turn from the fully screwed in position in order to create a 2mm gap (shown in figure 13). Hang the facia panel onto the outer cas- ing ensuring that the corresponding keyhole shaped holes engage the screwheads fully. Figure 14 2013 Focal Point Fires plc.
  • Page 8: Fitting The Decorative Frame

    13. Check the purpose provided ventilation is un-obstructed. 14. Light the fire and test setting pressures. 15. Check safe operation of the appliance by performing a combustion test as detailed in section 10.3. For specific servicing instructions, see relevant sections. 2013 Focal Point Fires plc.
  • Page 9: Servicing The Burner Unit

    It is important to note that the appliance can never be expect- ed to be 100% smoke tight and small quantities of smoke may be seen in corners of joints and gasket faces etc without affecting safety when the fire is in operation. 2013 Focal Point Fires plc.
  • Page 10: Testing For Firebox Leakage

    • Leakage occurring. Carry out leakage test and rectify any problems. • Combustible materials used in incorrect positions. • Airborne substances such as cleaning materials/air fresheners are being drawn through the fire. • Other airborne contaminants such as dust, tobacco smoke, paint vapours. 2013 Focal Point Fires plc.
  • Page 11 800mm (31.5”) measured from the top of the appliance glass panel. Combustible materials should not be positioned directly in front of the appliance within a distance of one metre. 2013 Focal Point Fires plc.
  • Page 12: Figure

    Example of moveable fireguard for portable heating appliances Example of detachable fireguard 1. Optional base section for total enclosure of a wall mounted appliance 1. Detachable fireguard 2. Points for attachment to a wall. 2. Screw eye 2013 Focal Point Fires plc.
  • Page 13: Ventilation & Room Size

    Any stubborn stains may be removed with a diluted liquid domestic bleach and water solution. Superficial scratches or stub- born stains can be smoothed out using a fine grade wet & dry sandpaper. Joints may be grouted using a matching tile grout. 2013 Focal Point Fires plc.
  • Page 14: Servicing

    Supplied by : Installer GAS SAFE registration No : Model : Fire serial No. : Date installed : 11.0 SERVICE HISTORY Date of service Serviced by (name): GAS SAFE No. : Contact details of Engineer 2013 Focal Point Fires plc.
  • Page 15: Guarantee - Terms And Conditions

    3G Service Department to the address below. Alternatively, you can email or fax.Please note that this does not affect your statutory rights. Focal Point Fires plc, 3G Service Department, Reid Street, Christchurch, Dorset, BH23 2BT. Alternatively email: 3g@focalpointfires.co.uk or fax. 01202 499326.

Table of Contents