Pioneer XV-S100DV Service Manual page 79

Dvd / cd receiver
Hide thumbs Also See for XV-S100DV:
Table of Contents

Advertisement

Description
FL
of Error
33 No FOK pulse during
When the focus was deviated continuously 20 times.
playback CLVA
If normal starting was impossible in the following three cases, disc-type sensing will be
retried if other errors occure excepting C5 error. However, when the focus error "33"
was occured continuously 3 times, it is finished as "38 error" at the moment:
38 Disc-type-
(1) startup with the first disc-type-sensing result, (2) forced startup with another disc by
sensing error
designating the disc type, (3) forced startup with the original disc by designating the disc
type.
SGC converge
39
SGC could not converge during detects the peak
timeout
41 Spindle timeout
The unit did not enter Stop mode within 10 seconds of issuance of a Stop command.
The spindle could not converge into within ± 12% of
the target FG rotation speed within 10 seconds after
spindle kick. The first time after startup (the first time
Spindle FG
after disc distinction), it doesn't become the number of
48
transition timeout
the target rotation within five seconds. The first time
after startup, detects the abnormal rotation number of
high-speed continuously 3 loops. DVD: 5 to 9 mS ,
CD: 40 to 60 mS
After the second times after startup, it doesn't become the number of the target rotation
Spindle PLL
49
within five seconds. Detects the abnormal high-speed or low-speed rotations. DVD: 5 to
transition timeout
9 mS , CD: 40 to 60 mS
4A Spindle lock timeout Spindle could not lock more than 1.5 seconds before start the AFB.
Auto sequence
ABUSY did not return within 1 second after the
timeout of peak
51
DDTCT (peak detection) command was sent.
detection
Auto sequence
ABUSY did not return within 30 mS after the FJMPD
52
timeout of focus
(Focus jump 1 to 0) command was sent.
jump down
Auto sequence
ABUSY did not return within 30 mS after the FJMPU
timeout of focus
53
(Focus jump 0 to 1) command was sent.
jump up
Auto sequence
ABUSY did not return within 50 mS after the GSUMON
54
timeout of play AGC
(play-AGC-measuring) command was sent.
Auto sequence
ABUSY did not return within 2 seconds after the
55
timeout of disc-type-
DJSRT (disc-sensing) command was sent.
sensing
ABUSY did not return within 1 second after the
Auto sequence
56
TBLOFS (Internal ATB after the completion of external
timeout of ATB2
ATB) command was sent.
Auto sequence
ABUSY did not return within 500 mS after the TSON
57
timeout of tracking
(tracking servo ON) command was sent.
servo ON
Auto sequence
ABUSY did not return within 200 mS after the TBL
58
timeout of ATB1
(external ATB) command was sent.
Auto sequence
ABUSY did not return within 2 seconds after the FGN
59
timeout of focus gain
(focus gain adjustment) command was sent.
adjustment
Auto sequence
ABUSY did not return within 2 seconds after TGN
5A
timeout of tracking
(tracking gain adjustment) command was sent.
gain adjustment
Auto sequence
ABUSY did not return within 1 second after the
5B
timeout of offset
CMDAVE (offset adjustment) command was sent.
adjustment
Causes if with a DVD
Causes if with a CD
Adjusts focus at the
innermost circumference
and tries to return to its
position where the error
was generated (for 3
times),then opens. If the
same error persists after
one retry, the tray opens.
(No FOK pulse)
Open
Open
Stop
Stops. (FG timeout)
Stops.
("73" is displayed during
starting process.)
Stops.
("73" is displayed during
starting process.)
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
XV-S100DV
Operation
of the Unit
79

Advertisement

Table of Contents
loading