Power Supply Connection - Olimpia splendid UNICO 8.5 HE Installation And Operation Manual

Olimpia splendid unico-he air conditioners installation and operation manual
Table of Contents

Advertisement

Available languages

Available languages

To position the external grating, proceed as follows:
- Grasp the two rubber belts attached to the grating in
one hand.
- Fold the outer gratings in half by grasping them with
your free hand along the fold line and inserting your
fingers inside the fins (fig. 11).
Insert your arm inside the pipe until the grating
protrudes all the way outside.
- Let the grating open, but keep your fingers inside the
fins.
- Turn the grating so that the fins are perfectly horizontal
with the inclination toward the outside (fig. 12).
- Pull the grating toward you.
- Tighten the rubber belts and fasten them to the two
pins on the inner flange.
- Cut the excess part of the belt.
Warning: If the external grating is accessible, to
prevent the hazards resulting from its possible
removal (insertion of the hands into the pipes and
touching moving or powered parts) it is absolutely
essential to fasten it to the wall with 4 anchor bolts
with a diameter of 6 mm.
2.3.4
The air conditioner is equipped with a power supply cable
Power supply
and plug.
connection
If it is installed near an outlet, you need only plug it in.
In this case, it is important to make sure the outlet to
which you are plugged in is effectively grounded and
connected to the mains by wiring of adequate size
(minimum 1.5 sq.mm. cross section).
To make an electrical connection with the shielded cable
(recommended for installations high on the wall) proceed
as follows:
Install a shunt box in the wall in the position shown on
the installation template (fig. 6), where you should provide
a power cable with a cross-section (two poles plus ground
wire) of 2,5 sq.mm.
Warning: The external power line should be provided
with an overload circuit breaker with suitable capacity
for the rating of the machine.
Make all connections in compliance with the laws in
effect.
Close the shunt box with its cover after drilling a hole in it
for passage of the cable.
Alternatively, you can use a cable in the wall in the position
shown on the template, for making the connection. In
this case, remove the casing (as described in paragraph
2.4.2) and connect the cable to the power terminal board.
Caution: these operations should be performed with
the machine already positioned on the bracket. Read
the instructions carefully before completely the
electric connection.