Junction Box Installation; Battery Backup - Heat & Glo Everest Owner's Manual

Hide thumbs Also See for Everest:
Table of Contents

Advertisement

Figure 12.1 Intellifi re Pilot Ignition (IPI) Wiring Diagram
E. Junction Box Installation
• Remove the screw attaching the junction box/receptacle
to the outer shell, rotate the junction box inward to dis-
engage it from the outer shell (see Figure 12.2).
• Pull the electrical wires from outside the appliance through
the opening into the valve compartment and secure wires
with a Romex connector. See Figure 12.2.
• Make all necessary wire connections to the junction
box/receptacle and reattach the junction box/receptacle
to the outer shell.
F. Battery Backup
This appliance may be operated on battery power in the
case of power outage. To operate the appliance turn both
the battery backup switch (right) and the main on/off switch
(left) to "on". To conserve battery life, turn the battery
backup switch "off" when not in use.
To replace the batteries, remove the screws holding the
control panel in place and pull it out. Be careful not to
disconnect any wires in the process.
NOTICE: Remotes or other 120 volt powered options will
not function during a power outage.
IGNITION MODULE
3 VAC
BATTERY
PACK
TRANSFORMER
3 VAC
PLUG IN
Figure 12.2 Junction Box Detail
Heat & Glo • Everest • 750-900 Rev. T • 5/12
I
S
WHT
ORG
GROUND TO
FIREPLACE
BLACK -
CHASSIS
RED +
PIGGYBACK
ON/OFF
SWITCH
VALVE
GRN wire
inside box
NOTICE: DO NOT wire
110 VAC to wall switch.
(Appearance may vary per model)
INTERMITTENT
PILOT
IGNITOR
Romex
Connector
14/2WG
Cover Plate
outside firebox
Copper
ground attached
to GRN screw with
GRN wire
41

Advertisement

Table of Contents
loading

Table of Contents