Advertisement

Models:
EXCLAIM-36

Woodburning Fireplace

Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING
If the information in these instruc-
tions is not followed exactly, a
fi re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re. Overfi ring will void your war-
ranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to comply
may cause house fi re.
Installation and service of this fi replace should
be performed by qualifi ed personnel. Hearth
& Home Technologies suggests NFI certifi ed
or factory-trained professionals, or technicians
supervised by an NFI certified
professional.
Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06
(Traditional refractory shown.)
CAUTION
DO NOT DISCARD THIS MANUAL
Read, understand
and follow these
instructions for safe
i n s t a l l a t i o n a n d
operation.
Owner's Manual
Installation and Operation
Leave this manual with
party responsible for
use and operation.
WARNING
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
Glass and other surfaces are hot
during operation and cool down.
Keep children away.
CAREFULLY SUPERVISE children in same room
as fi replace.
Alert children and adults to hazards of high
temperatures.
Keep clothing, furniture, draperies and other
combustibles away.
WARNING
Fire Risk
For use with solid wood fuel or decorative
gas appliance only.
Do not install unvented gas logs.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EXCLAIM-36 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Heat & Glo EXCLAIM-36

  • Page 1: Woodburning Fireplace

    For use with solid wood fuel or decorative or factory-trained professionals, or technicians gas appliance only. supervised by an NFI certified • Do not install unvented gas logs. professional. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 2 DECORATIVE GAS APPLIANCE IN THE FIREPLACE, CONTACT: HEARTH & HOME TECHNOLOGIES INC., ADJUST DAMPER TO THE FULLY OPEN POSITION. 1915 W. SAUNDERS ST., MT. PLEASANT, IA 52641. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 3: Table Of Contents

    A. Gas Log/Lighter Provisions ....24 Note: An arrow ( ) found in the text signifi es change in content. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 4: Listing And Code Approvals

    Hearth & Home Technologies. Hearth & Home Technologies disclaims any responsibility for, and the warranty and agency listing will be voided by the above actions. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 5: Getting Started

    Basement installations should be avoided due to stack effect. Stack effect creates negative pressure in lower levels. Hearth & Home Technologies recommends the use of direct vent fi replaces in basements. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 6 Consider the fi replace location relative to fl oor and ceiling and attic joists. Recommended Recommended Location Location Marginal Location Location Recommended Location Recommended Windward Outside Air Intake Leeward Multi-level Roofs Figure 2.1 Recommended Chimney Locations Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 7: Typical Fireplace System

    V-shaped standoffs (spacers) Mantel and surround Decorative facing and trim Hearth extension Outside combustion air Factory-built fireplace Protective metal hearth strip(s) Figure 2.2 Typical Fireplace System Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 8: Tools And Supplies Needed

    Read all the instructions before starting the installation. Follow these instructions carefully during the • Keep fi replace dry. installation to ensure maximum safety and benefi t. • Mold or rust may cause odors. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 9: Selecting Fireplace Location

    As a room divider 28 in. (711 mm) 48 in. (1219 mm) EXCLAIM-36 49-1/2 With Outside 1257 45-1/2 Without Outside Air 1156 Figure 3.1 Fireplace Locations Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 10: Clearances

    1 in. (25 mm) to side of appliance 0 in. (except at nailing flanges where it is 1/2 in. (13 mm)) to floor Figure 3.2 Clearances to Combustible Materials Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 11: Sidewalls/Surrounds

    Use only noncombustible material below the top of the front standoffs. 45-1/2 in. (1156 mm) 28 in. (711 mm) Figure 3.4 Framing the Fireplace Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 12: Construct The Chase

    fi replace Figure 3.5 Chase Assembly • Maximum unsupported chimney above 1.83 roof Note: A maximum of two pairs of offsets and returns may be used. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 13: Installation Of Fireplace

    fi replace. See Figure 4.4 for handle location/operation. Flexible Duct (not supplied) Outside Air Plate Outside Air Assembly Shield 2 Wire Ties Figure 4.1 Outside Air Installation Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 14 Figure 4.3 Outside Combustion Air Placement Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 15: Secure The Fireplace

    fi replace opening for square. Measure diagonal dis- tances of the opening to make sure they are equal. If they are not, continue to shim the fi replace until those diagonals are equal. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 16: Chimney Assembly

    NOTE: • Chimney performance may vary. • Trees, buildings, roof lines and wind conditions affect performance. • Chimney height may need adjustment if smoking or overdraft occurs. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 17: Chimney Requirements

    Do NOT connect this fireplace to a chimney flue servicing another appliance. SL1136 34-3/4 • Do NOT connect to any air distribution duct or SL1148 46-3/4 1187 system. * Dimensions refl ect effective height. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 18: Using Offsets/Returns

    2511 Proper assembly of air cooled chimney parts results in an overlap of chimney joints of 1-1/4 in. (32 mm). Effective length is built into this table. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 19: Assemble The Chimney Sections

    fl oor or every 10 ft (3.05 m) of clear space. • Use same dimensional lumber as joists. Ceiling fi restop slows spread of fi re and reduces cold air infi ltration. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 20: Install The Attic Insulation Shield

    • Straight chimney sections may be secured with screws (not to exceed 3/4 in./19 mm in length) at the joints. Keep chimney sections from separating or twisting. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 21: Complete The Enclosure

    If a roof fl ashing is to be used, install the roof fl ashing appropriate to the roof pitch and install a round termination cap and storm collar following the instructions shipped with the cap. Figure 6.3 Ceiling/Attic Construction Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 22: Chase Top

    2 in. (51 mm) min. 14-1/2 in. (368mm) max. Top of Pipe 1-1/2 in. (38 mm) min. overlap Figure 6.6 Installing a TR11T Round Telescoping Termination Cap Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 23 7 in. (178 mm) below top of the chase. Top of Pipe Figure 6.9 Installing a European Copper Series Termination Cap (CT3-King shown) Figure 6.8 Installing a TCT1175 Terra Cotta Cap Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 24: Accessories

    Repack beyond 4 in. (102 mm) Insulation from fireplace side. Knockout 4 in. (102 mm) Figure 7.1 Gas Line Installation Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 25: Finishing

    Ceramic Tile 12.50 0.08 14-5/8 in. Armstrong™ Privacy Guard Plus .046 2.18 1/2 in. Figure 8.3 Hearth Extension Dimensions Marble 14.3-20.0 0.07-0.05 16-5/8 in. - 23-3/8 in. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 26 12 in. Hearth Extension (305 mm) 12 in. Min. (305 mm) 30 in. (762 mm) Min. min. Noncombustible Material Micore Hearth Strip Figure 8.5 Flush Hearth Extension Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 27: Finishing Material

    Figure 8.7. Short stub walls are also acceptable if they are refer to the manual packed with each set of doors for instal- contained within the shaded area. lation instructions. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 28: Operating Instructions

    Do not install unvented gas logs. maintain the system in top operating condition. open Damper Handle Handle up - open Handle down - closed Figure 9.1 General Operating Parts Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 29: Outside Air

    • Doors must be fully opened or fully closed when operating fi replace. Partially opened doors may draw fl ame, smoke or heat from fi replace. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 30: Grate

    This sounds ridiculous but that is exactly what you are • Closer than required clearances to doing if you burn unseasoned wood. combustibles to fi replace. • Within space required for loading or ash removal. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 31: Starting A Fire

    fi replace and the refractory and paint to cure. You may Combustible materials may ignite. notice an industrial odor the fi rst few fi res. This is consid- ered normal. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 32: Troubleshooting

    Creosote buildup in flue? Air register from furnace near fireplace? Damper closed? Doors opening and closing? Outside air Window closed closed? for start-up? Figure 10.1 Factory-built Fireplaces: Troubleshooting Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 33: Diagnostics And Problem Solving

    No: Need for all heat boosts possible How much heat output do you • Unrealistic expectations Explanation of decorative nature of fi replace; suggestion of expect? approved fi replace insert. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 34 Is the chimney clean? • No: Creosote odor Have chimney cleaned. • Yes: Damper closed too early Wait until fi re completely out before closing damper. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 35: Maintenance And Servicing The Fireplace

    European Copper Series TR11/TR11T TCT1175 ST1175 Termination Cap Round Termination Cap Square Termination Cap Terra Cotta Termination Cap (CT3-King shown) Figure 11.1 Chimney & Termination Cap Cleaning Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 36: Maintenance Task List

    Failure to replace damaged components and make conduct a minimum of an NFPA 211 Level 2 inspection of proper repairs creates risk of fi re. the chimney. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 37: Reference Materials

    8-5/8 in. 9-1/4 in. (219 mm) (235 mm) 9-5/8 in. 18-1/2 in. 9-1/2 in. 36 in. 7-5/8 in. (470 mm) (244 mm) (241 mm) (194 mm) (914 mm) Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 38: Fireplace Components

    AK22 - Outside Air Kit Traditional Brick Pattern Refractory 66 in. (1676 mm) 20 in. (508 mm) HX4 - Hearth Extension 1/2 in. (13 mm) Herringbone Pattern Refractory Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 39: Chimney Components

    (133 mm) (279 mm) 4 in. (102 mm) 13 in. (330 mm) Outside CAK5A - Chimney Air Kit Diameter 13 in. (330 mm) SL11 - Chimney Stabilizer Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 40 (1013 mm) RF571 - Roof Flashing 13 in. 2 in. (330 mm) (51 mm) JB577 - Chimney Joint Band 13 in. (330 mm) CB576 - Chimney Joint Band Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 41 (508 mm) LDS-BV Decorative Shroud 17 in. (432 mm) 9-3/8 in. Catalog # (238 mm) 12-1/2 15-1/2 LDS-BV 9-1/4 in. (235 mm) TCT1175 - Terra Cotta Cap Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 42 CT3-Queen 16 in. (406 mm) 21 in. (533 mm) 31-7/8 in. (810 mm) 24-3/4 in. (629 mm) 18 in. 20-5/8 in. (457 mm) (524 mm) CT3-Knight CT3-Pawn Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 43: Woodburning Termination Cap

    Minimum height is established with the bottom of the termination cap 7 in. (178 mm) above the chase top. Minimum height must increase accordingly for any height above 7 in. (178 mm). All dimensions are INSIDE dimensions. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 44: Service Parts

    D. Service Parts EXCLAIM-36 SERIES Service Parts Beginning Manufacturing Date: N/A Exploded Parts Diagram Ending Manufacturing Date: Active 36 in. Woodburning Fireplace Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 45 33271 4 in. Outside Air Inlet Ring 25692 25692 AK22 Installation Instructions 31170 31170 Installation Instructions & Owner’s Manual 4013-039 4013-039 Powder Coat Touch-Up Paint 71479 71479 Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 46 This page intentionally left blank. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 47: Limited Warranty

    HHT reserves the right to make changes at anytime, without notice, in design, material, specifications and prices and the right to discontinue styles and products. Feb 2006 Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...
  • Page 48: Contact Information

    6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Heat & Glo • EXCLAIM-36 Woodburning Fireplace • 4013-039 Rev L • 10/06...

Table of Contents