IBM Midrange System DS4000 Series Hardware Manual page 214

Midrange system storage ds4000/ds5000 series
Hide thumbs Also See for Midrange System DS4000 Series:
Table of Contents

Advertisement

7. The Customize Advanced Logical Drive Parameters window opens (Figure 4-61). You can
set your new logical drive using any of the predefined I/O types listed, or manually set the
cache read ahead multiplier, segment size, and controller ownership.
a. For logical drive I/O characteristics, you can specify file system, database, or
multimedia defaults. The Custom option allows you to disable or enable the dynamic
cache read prefetch and the segment size. Table 4-9 shows the defaults predefined for
each I/O type.
Table 4-9 Logical drive defaults I/O characteristics
196
IBM Midrange System Storage Hardware Guide
I/O type
Segment size
Modification priority
Read cache
Write cache
Write cache without
batteries
Write cache with
mirroring
Flush write cache after
10 seconds
Dynamic cache
prefetch
Enable background
media scan
Media scan with
redundancy check
Pre-read redundancy
check
File system
Database
128 K
128 K
High
High
Enable
Enable
Enable
Enable
Disable
Disable
Enable
Enable
10 seconds
Enable
Enabled
Enable
Enable
Disable
Disable
Disabled
Disabled
Multimedia
256 K
High
Enable
Enable
Disable
Enable
10 seconds
Enable
Enable
Disable
Disabled

Advertisement

Table of Contents
loading

Table of Contents