Safety Instructions - Emerson Designer Remote CF759AB03 Owner's Manual

Designer remote series
Table of Contents

Advertisement

WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.
1. Read your owner's manual carefully and keep it for future reference.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel
disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the
service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off
the power to the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not
operate fan without blades.
2. All wiring must be in accordance with the National Electrical Codes "ANSI/NFPA 70-1999" and
Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling
fan must be grounded as a precaution against possible electrical shock. Electrical installation
should be made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least
50 pounds. Use only U.L. outlet boxes listed as acceptable for fan support, and use the mounting
screws provided with the outlet box. Most outlet boxes commonly used for support of light
fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified
electrician if in doubt.
4. The downrod furnished with the fan provides the minimum recommended floor to fan blade
clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental
contact with the fan blades.
6. The fan must be installed on a level ceiling. Do NOT install the fan on a sloped or cathedral
ceiling, unless the outlet box is installed so that the mounting surface (the bottom of the outlet
box) is level. The receiver will be damaged, resulting in an inoperable fan and a possible electrical
fire.
7. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do
not know enough about electrical wiring, have your fan installed by a licensed electrician.
WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not
specifically approved for this fan.
WARNING: This product is designed to use only those parts supplied with this product and/or any
accessories designated specifically for use with this product by Emerson. Substitution of parts or
accessories not designated for use with this product by Emerson could result in personal injury or
property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the
blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between
rotating fan blades.
WARNING: To reduce the risk of electric shock, this fan must be installed with an isolating wall
control/switch.
DATE CODE:
The date code of this fan may be found on the box, stamped in ink on a white label.
You should record this data above and keep it in a safe place for future use.
WARNING
!

Safety Instructions

2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents