Emergency Keys - DSC PowerSeries PK5500 Installation Instructions Manual

Hide thumbs Also See for PowerSeries PK5500:
Table of Contents

Advertisement

Programming the Keypad
There are several programming
Toggle Option
options available for the keypad.
These are described below. Pro-
1 _ _ 4 _ _ _ _
gramming the keypad is similar
to programming the rest of the system. When you are in the keypad pro-
gramming sections, the keypad will display which options are turned on
along the top of the display. To turn an option on or off, press the number
corresponding to the option on the number pad. The numbers of the options
that are currently turned ON will be displayed. For example, if options 1
and 4 are on, the display will look like diagram shown on the different key-
pad displays.
For information on programming the rest of your security system, please
refer to your system's Installation Manual.
Broadcasting LCD Labels
All LCD programming is done per keypad. If more than one LCD keypad is
present on the system, labels programmed at one keypad can be broadcast
to all other LCD keypads. Perform the following procedure in order to broad-
cast labels:
Step 1 - Program one LCD keypad completely.
Step 2 - Make sure all LCD keypads are connected to the Keybus.
Step 3 - Enter keypad programming by pressing [,][8][Installer
Code][,], then enter section [998] at the keypad that was programmed.
The keypad will now broadcast all the information programmed to all the
other LCD keypads on the system.
Step 4 - When the keypad is finished press the [#] key to exit.
NOTE: LCD Label broadcast from this keypad is only compatible
with other PK5500 keypads.
Language Programming
Hold (<>) keys for 2 seconds to enter language programming, scroll to
the desired language and Press [,] to select.
NOTE: If section [077] option 4 is OFF, language programming
can only be performed while in installers programming.
Enrolling the Keypad
The keypad will need to be assigned to a partition and slot if supervision or
keypad zones are being used. Keypad assignments and keypad option pro-
gramming must be done at each keypad individually.
The 1st digit of keypad assignment is used to determine partition assign-
ment (1 to 8). If partitioning is not used, enter [1]. For Global Keypads,
enter [0].
The 2nd digit of keypad assignment is used to determine slot assignment
for keypad supervision. Each keypad will be assigned a different slot num-
ber from 1 to 8. PK5500 LCD keypads come defaulted in slot 8. If LCD key-
pads are used one LCD keypad must remain in slot 8.
Enter the following at each keypad installed on the system:
1. Enter Installer Programming by pressing [,][8][Installer's Code]
2. Press [000] for Keypad Programming
3. Press [0] for Partition and Slot Assignment
4. Enter the 1st digit (0 to 8 for partition assignment)
5. Enter the 2nd digit (1 to 8 for slot assignment supervision)
6. Press the [#] key twice to exit programming.
7. After assigning all keypads, perform a supervisory reset by entering
[,][8][Installer's Code][902] and wait for 60 seconds.
8. Press the [#] key to exit programming after 60 seconds.
Programming Labels
1. Enter keypad programming by pressing [,][8][Installer Code][,]. Enter
the 3-digit section number for the label to be programmed.
2. Use the arrow keys (<>) to move the underline bar underneath the let-
ter to be changed.
3.
Press the number keys [1] to [9] corresponding to the letter you require.
The first time you press the number the first letter will appear. Pressing the
number key again will display the next letter
[1] - A, B, C, 1 [4] - J, K, L, 4 [7] - S, T, U, 7 [0] - Space
[2] - D, E, F, 2 [5] - M, N, O, 5 [8] - V, W, X, 8
[3] - G, H, I, 3 [6] - P, Q, R, 6 [9] - Y, Z, 9,0
4. When the required letter or number is displayed use the arrow keys
(<>) to scroll to the next letter.
5. When you are finished programming the Zone Label, press the [,] key,
scroll to "Save," then press [,].
6. Continue from Step 2 until all Labels are programmed.
ASCII Characters
Changing Brightness/Contrast
1. Press [,][6][Master code].
2. Use the [<][>] keys to scroll to either Brightness Control or Contrast
Control.
3. Press [,] to select the setting you want to adjust.
4. a) 'Brightness Control': There are multiple backlighting levels. Use the
[<][>] keys to scroll to the desired level.
b) 'Contrast Control': There are 10 different display contrast levels. Use the
[<][>] keys to scroll to the desired contrast level.
5. To exit, press [#].
Changing the Buzzer Level
1. Press [,][6][Master Code].
2. Use the [<][>] keys to scroll to Buzzer Control.
3. There are 21 different levels, use the [<][>] keys to scroll to the
desired level.
4. To exit, press [#].

Emergency Keys

Press the (
.
Press both (
Panic transmission.
Broadcasting Door Chime
All door chime programming is done per keypad. If more than one key-
pad is present on the system, door chime programmed at one keypad can
be broadcast to all other keypads. Perform the following procedure in
order to broadcast door chime:
Step 1 - Program one keypad completely.
Step 2 - Make sure all keypads are connected to the Keybus.
Step 3 - Enter keypad programming by pressing [,][8][Installer
Code][,], then enter section [994] at the keypad that was pro-
grammed. The keypad will now broadcast all the door chime infor-
mation programmed to all the other keypads on the system.
Step 4 - When the keypad is finished press the [#] key to exit.
) key for 2 seconds to send a Fire transmission.
) keys simultaneously for 2 seconds to send a

Hide quick links: