Page 1
PK5500 v1.3 Installation Instructions / 安装说明 WARNING: Please refer to the System Installation Manual for information on limitations regarding product use and func- tion and information on the limitations as to liability of the manufacturer. NOTE: These instructions shall be used in conjunction with the system Installation Manual of the Control Panel with which this equipment is intended to be used.
The PK5500 keypad can be used on security systems with up to 64 1. Secure Keypad to wall using mounting holes. Use all 4 screws provided zones. These keypads are compatible with the latest version of the foll- unless mounting on a single gang box.
Each keypad will be assigned a different slot num- EN50131-1 Grade 2, Class II ber from 1 to 8. PK5500 LCD keypads come defaulted in slot 8. If multi- Operating Instructions shall be made available to the user.
Keypad Enrollment Enter keypad programming by pressing [,][8][Installer’s Code][000]. [0] Partition / Slot Assignment Digit Option Valid Range Default Partition Assignment (0=Global Keypad) 0 to 8 I________I Slot Assignment 1 to 8 I________I [1]-[5] Function Key Assignment Function Key Button Valid Range Default Function...
Page 5
[065] Fire Alarm Label (28 Characters) Default:“Fire Zone” I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I [065] I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I [066] Fail to Arm Event Message Default: “System Has Failed to Arm” I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I [066] I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I [067] Alarm When Armed Event Message Default: “Alarm Occurred While Armed < >” I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I [067] I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I [071] First User Display Mask...
Page 6
[074] Key Options Default Option I____I [F]ire Key Enabled [F]ire Key Disabled For Future Use I____I I____I [P]anic Key Enabled [P]anic Key Disabled For Future Use I____I [076] First Keypad Options Default Option I____I Display Code when Programming Display “Xs” when Programming Local Clock Display ON Local Clock Display OFF I____I...
Page 7
[120]-[151] Command Output Labels Default: “Command_O/ P_1” - “Command_O/P_4” For Partition 1 Command O/P 1 to 4 enter [120] to [123] For Partition 5 Command O/P 1 to 4 enter [136] to [139] For Partition 2 Command O/P 1 to 4 enter [124] to [127] For Partition 6 Command O/P 1 to 4 enter [140] to [143] For Partition 3 Command O/P 1 to 4 enter [128] to [131] For Partition 7 Command O/P 1 to 4 enter [144] to [147]...