10-1. Installation Diagram of Indoor and Outdoor Units
Flat head
8
wood screw
10 Battery cover
9
Flat head wood screw
5
3
Batteries
2
Wireless remote control
The provided Remote Controller is a
wireless type, which also can be used
as a wire.
Please see "How to Connect The Remote
Controller for Wired Operation", in case of
wired control is required.
When installing the outdoor unit,
leave open in at least two of direction
(A), (B), (C) and (D) shown in the
fi gure on the right.
Remark :
Detail of accessory and installation
parts can see in the accessory sheet.
Some pictures might be different from
the actual parts.
Before installing the wireless remote controller
• Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (− ) positions.

10. INSTALLATION PROCEDURE

6
8
Flat head
wood screw
Vinyl tape
Apply after carrying
out a drainage test.
(C)
(B)
2 Wireless remote controller
48
Hook
1
Installation
plate
Shield pipe
Remote control holder
4
(D)
Saddle
Extension
drain hose
(Not available,
provided by installer)
(A)
3 Batteries
FILE NO. SVM-12070
For the rear left and left piping
Wall
Insert the cushion between the
indoor unit and wall, and tilt the
indoor unit for better operation.
Do not allow the drain hose to get
slack.
Cut the piping
hole sloped
slightly.
Make sure to run the drain hose
sloped downward.
The auxiliary piping can be
connected to the left, rear left, rear
right, right, bottom right or bottom
left.
Right
Rear right
Rear
Left
Bottom right
left
Bottom left
Insulate the refrigerant pipes
separately with insulation, not
together.
8 mm thick heat resisting
polyethylene foam