8. Louver control

This function controls the air direction of the indoor unit.
1) Louver
• The position is automatically controlled according to the operation
position
mode (COOL/HEAT).
• The set louver position is stored in memory by the microcomputer,
and the louver returns to the stored position when the next operation
is performed. (Cooling/heating memory position)
The angle of the louver is indicated as the horizontal angle is 0°.
1) Louver position in cooling operation
2) Louver position in heating operation

2) Air direction adjustment

Horizontal
blowing

3) Swing

• Swing operation is performed in width 35° with the stop position as
the center.
• If the stop position exceeds either upper or lower limit position, swing
operation is performed in width 35° from the limit which the stop
position exceeded.
Operation flow and applicable data, etc.
Cooling operation/
AUTO (COOL)
Initial setting of "Cooling storage position"
Louver : Horizontal blowing (37.4°)
Heating operation/
AUTO (HEAT)
Initial setting of "Heating storage position"
Louver : Directs downward (76.9°)
Air direction
Inclined
Blowing
blowing
downward
Inclined
Horizontal
blowing
blowing
34
FILE NO. SVM-12070
Description
• The louver position can
be arbitrarily set up by
pushing [FIX] button.
• Swing
When pushing [SWING]
button during operation,
the louver starts
swinging.