Sanyo PLC-EF60 Service Manual page 49

Multimedia projector
Hide thumbs Also See for PLC-EF60:
Table of Contents

Advertisement

Electrical Adjustments
Group
No.
Item
18
DIMMER CTRL LEVEL10
19
DIMMER CTRL LEVEL11
20
DIMMER CTRL LEVEL12
21
DIMMER CTRL LEVEL13
22
DIMMER CTRL LEVEL14
23
DIMMER CTRL LEVEL15
24
DIMMER AVE POINT
50
Auto-Picture Control
0
Auto-Picture Control Forced OFF
60
Remote Control
0
PAD_REPEAT
1
PAD Defeat Area in X direction
2
PAD Defeat Area in Y direction
3
Wheel Move in X Direction
4
Wheel Move in Y Direction
5
Wheel Valid Angle in X Direction
6
Wheel Valid Angle in Y Direction
70
COOLING
0
COOLING_TIME
1
FAN_OFF_TIME
80
Projector Use time
0
PJ Time
1
Display PJ Time in Special Menu
2
PJ Time Reset
90
Operation History
0
OPERATION_HISTORY_1
~
49
OPERATION_HISTORY_50
110
Lamp Total On Time
0
Lamp 1
1
Lamp 2
111
Lamp On Time
0
Lamp 1
1
Lamp 2
112
Lamp Config
0
Lamp Config Change (300W)
1
Lamp Config Change (200W)
2
Lamp Config Change (100W)
113
Lamp Reset Counter
0
Lamp 1 Reset Counter
1
Lamp 2 Reset Counter
114
Lamp Time Information(LAMP1)
0
Lamp Normal Time
1
Lamp Eco Time
2
Lamp Total Time
115
Lamp Time Information(LAMP2)
0
Lamp Normal Time
1
Lamp Eco Time
2
Lamp Total Time
120
RC KEY Disable
0
RC Zoom & Focus Only
1
RC / KEY All
2
Operation after Power Fail
140
Fan Control
0
Service Operate Target MODE
1
Service Operate Target FAN
2
Control Switch
3
Fan Out LimitVoltMAX
4
Fan Out LimitVoltMIN
5
Fan Out LimitDACMAX
6
Fan Out LimitDACMIN
7
Manual Out
8
Now Out
141
Fan Optiion
Function
Bright level10 data: Bright level10 when less than the value
Bright level11 data: Bright level11 when less than the value
Bright level12 data: Bright level12 when less than the value
Bright level13 data: Bright level13 when less than the value
Bright level14 data: Bright level14 when less than the value
Bright level15 data: Bright level15 when less than the value
Average point data for dimmer
0:follows to Menu, 1:Forced OFF
Excutes when receiving PAD code N times
PAD defeat area from the center of X-axis
PAD defeat area from the center of Y-axis
Valid movable value of Wheel in X-axis
Valid movable value of Wheel in Y-axis
Valid angle value of Wheel in X-axis
Valid angle value of Wheel in Y-axis
Cooling time period after power off
Cooling time period after set into standby mode
Projector accumulated use time in hours
0:Disable1:Enable
Reset PJ Time when the value to 10
Operation history in last operation
Operation history last 50th operation
Accumulated Lamp-on time of Lamp 1
Accumulated Lamp-on time of Lamp 2
Lamp-on time of Lamp 1
Lamp-on time of Lamp 2
Lamp life selection for 300W(Step : 500h)
Lamp life selection for 200W(Step : 500h)
Lamp life selection for 100W (Step : 500h)
Reset times of the Lamp1 time counter
Reset times of the Lamp2 time counter
Lamp-on time with the normal mode
Lamp-on time with the eco mode
Total Lamp-on time with the coefficient
Lamp-on time with the normal mode
Lamp-on time with the eco mode
Total Lamp-on time with the coefficient
0:Enable / 1:Disable
0:Enable / 1:RC Disable /2:KEY Disable
0:deos not recover with key input / 1:recover with key input
Target Mode -1:according to current mode 0: Normal mode1: Eco mode
Target Fan0:A1:B2:C3:D14:D25:E
Control switch oftarget Fan0:Auto1:Manual
Max. voltage limit of target Fan * Voltage=Value/100
Min. voltage limit of target Fan * Voltage=Value/100
DAC output for Max. Voltage limitation
DAC output for Min. Voltage limitation
Voltage in manual mode for target Fan in 0.01V unit
Current voltage of target Fan
- 49 -
Range
Initial Value
0~32767
750
0~32767
825
0~32767
900
0~32767
975
0~32767
1050
0~32767
1125
1~16
4
0 / 1
0
8-40
8
0-127
48
0-127
48
32-255
64
32-255
64
0-45
30
0-45
30
10-120
90
10-60
30
0 ~ 9999
0
0 / 1
0
0 ~ 10
0
0~32767
0
0~32767
0
-
0
-
0
-
0
-
0
1000 ~20000
1500
1000 ~ 20000
1500
1000 ~ 20000
10000
-
0
-
0
-
-
-
-
-
-
-
-
-
-
-
-
0 / 1
0
0/1/2
0
0 / 1
0
-1~3
-1
0~5
0
0 / 1
0
0 ~ 2000
0 ~ 2000
0~255
0~255
0~2000
-
-

Advertisement

Table of Contents
loading

Table of Contents