Service Adjustment Data Table - Sanyo PLC-EF60 Service Manual

Multimedia projector
Hide thumbs Also See for PLC-EF60:
Table of Contents

Advertisement

Electrical Adjustments

4. Service Adjustment Data Table

Group
No.
Item
0
Thermal Monitor Read only
0
LM76(Temp) Monitor
1
LM76(Temp) Monitor
2
Thermistor Monitor
1
Atmosphere Monitor Read only
0
MPXA4114A(Pressure) Monitor
1
MPXA4114A(Pressure) Monitor
2
MPXA4114A(Pressure) Monitor
2
Airflow sensor Monitor Read only
0
Airflow Monitor
3
Acceleration sensor Monitor Read only
0
MAS1390 (Acceleration) Monitor
4
Lens position sensor Read only
0
Lensshift T/B Position Monitor
1
Lensshift L/R Position Monitor
2
Zoom Position Monitor
3
Focus Position Monitor
5
Fan voltage sensor, Read only
FAN A Monitor
FAN B Monitor
FAN C Monitor
FAN D1 Monitor
FAN D2 Monitor
FAN E Monitor
10
RS232C Setting
0
Baudrate
1
RTS/CTS Flow Control
2
CTS Timeout Second
3
Serial Address
11
Lan Card Setting
0
LAN Card Switch
20
Logo prohibition
0
Logo prohibition
30
Color Shading/Gamma
0
Color Shading Correction On/Off
1
Gamma Correction On/Off
40
Dimmer Control
0
Dimmer Level
1
DIMMER AREA NORMAL HS
2
DIMMER AREA NORMAL HR
3
DIMMER AREA NORMAL VS
4
DIMMER AREA NORMAL VR
5
DIMMER AREA WIDE HS
6
DIMMER AREA WIDE HR
7
DIMMER AREA WIDE VS
8
DIMMER AREA WIDE VR
9
DIMMER CTRL LEVEL1
10
DIMMER CTRL LEVEL2
11
DIMMER CTRL LEVEL3
12
DIMMER CTRL LEVEL4
13
DIMMER CTRL LEVEL5
14
DIMMER CTRL LEVEL6
15
DIMMER CTRL LEVEL7
16
DIMMER CTRL LEVEL8
17
DIMMER CTRL LEVEL9
These initial values are the reference data written from the
CPU ROM to memory IC when replaced new memory IC. The
adjustment items indicated with "✻" are required to readjust
following to the "Electrical adjustments". Other items should be
used with the initial data value.
Function
Thermal sensor (Intake duct) [iic error =999]
Thermal sensor (Inside) [iic error =999]
Thermistor (Panel) [iic error =999]
Atmosphere sensor
Atmosphere sensor [unit: mmHg]
Atmosphere sensor [unit:hpa]
Airflow sensor
Acceleration sensor
Voltage = value /100
Voltage = value /100
Voltage = value /100
Voltage = value /100
Voltage = value /100
Voltage = value /100
* Do not change setting when using LAN card
RS232C Baudrate (0:9600 / 1:19200)
RS232C RTS/CTS Flow Control(0:Disable / 1:Enable)
RS232C CTS Timeout value
Unique address for the projector when using RS232C daisy chain use
LAN (0: Disable / 1: Enable)
Logo prohibition(0: Menu / 1: Forced)
Color Shading Correction (0:Off / 1:On)
Gamma Correction (0:Off / 1:On)
0:250 ~ 15:300W Effect only 300W
Acquisition range of bright level data for dimmer HS(Normal Screen)
Acquisition range of bright level data for dimmer HR(Normal Screen)
Acquisition range of bright level data for dimmer VS(Normal Screen)
Acquisition range of bright level data for dimmer VR(Normal Screen)
Acquisition range of bright level data for dimmer HS(Wide Screen)
Acquisition range of bright level data for dimmer HR(Wide Screen)
Acquisition range of bright level data for dimmer VS(Wide Screen)
Acquisition range of bright level data for dimmer VR(Wide Screen)
Bright level1 data: Bright level1 when less than the value
Bright level2 data: Bright level2 when less than the value
Bright level3 data: Bright level3 when less than the value
Bright level4 data: Bright level4 when less than the value
Bright level5 data: Bright level5 when less than the value
Bright level6 data: Bright level6 when less than the value
Bright level7 data: Bright level7 when less than the value
Bright level8 data: Bright level8 when less than the value
Bright level9 data: Bright level9 when less than the value
- 48 -
Range
Initial Value
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0 / 1
1
0 / 1
0
0 ~ 255
0
0 ~ 999
1
0 / 1
1
0 / 1
0
0 / 1
1
0 / 1
1
0 ~ 15
15
0~2047
43
0~2047
1067
0~2047
4
0~2047
772
0~2047
43
0~2047
1067
0~2047
100
0~2047
676
0~32767
75
0~32767
150
0~32767
225
0~32767
300
0~32767
375
0~32767
450
0~32767
525
0~32767
600
0~32767
675