92 | Installation Equipment |
LBB 4115/00
Tap-Off Unit
The LBB 4115/00 is used to create short-circuit proof
tap-off points on the trunk-line cabling. Each tap-off
point allows for connection of up to four channel selec-
tor panels or up to two table-top contribution units
such as delegate-, chairman- or interpreter desks. A
Tap-Off Unit consists of two tap-off points. The Tap-
Off Unit comes complete with cable restraining clamps
and includes mounting holes for fixing purposes.
Interconnection
• 2 m (78.74 in) long cable terminated with a moulded 6-pole
circular connector
• 6-pole circular connector for loop-through connections
• 2 x 6-pole circular connector for tap-off purposes. Each tap-
off is equipped with an electronic short-circuit protection
facility on the power supply lines
Technical data
Dimensions (H x W x D)
35 x 49 x 140 mm (1.37 x 1.91 x 5.51 in)
Weight
approx. 0.3 kg (0.66 lb)
Colour
charcoal (PH 10736)
LBB 4116/xx
Extension Cable Assembly
Cable terminated at both ends with a moulded 6-pole
circular connector (male and female). The extension to
the type number gives the length of the cable.
Technical data
Grey PVC sheath
Ordering information
LBB 4116/02
LBB 4116/05
LBB 4116/10
LBB 4116/15
LBB 4116/20
LBB 4116/25
LBB 4117/00
Set of 25 Cable Locking Clamps
Matching clamps for male/female cable connectors such
as those on the Extension Cable LBB 4116/xx. One
clamp per male/female connector required.
DCN Data Brochure
6 mm (0.24 in) dia.
2 m (78.74 in) length
5 m (196.85 in) length
10 m (393.70 in) length
15 m (590.55 in) length
20 m (787.40 in) length
25 m (984.25 in) length
LBB 4116/00
100 m Installation Cable
100 m (328 ft) roll of cable identical to LBB 4116/xx
but without connectors.