HYT TC-265 Service Manual page 10

Table of Contents

Advertisement

Function Setting:
Function
Function
No.
Name
1
Monitor
2
Channel
Scan
3
Priority
4
Priority
Channel
5
Look
Back A
6
RX Dwell
Time
7
Dropout
Delay
Time
8
TX Dwell
Time
9
Talk Back
Setting (Defaults are
underlined)
OFF
Monitor Momentary
Monitor Lock
SQ OFF Momentary
OFF
CO
TO
OFF
ON
0, 1-16
0
0.5-5.0s
1.0s
(step: 0.1s)
0.5-5.0s
3.0s
(step: 0.1s)
0.1-5.0s
3.0s
(step: 0.1s)
0.1-5.0s
3.0s
(step: 0.1s)
Current
Start + Last Stopped
TC-265/365 SERVICE MANUAL
Display
1
OFF
Disable
1
1
AF channel opens when [MONI] is
held down.
1
2
Squelch opens when [MONI] is held
down. Switches each time [MONI] is
held down.
1
3
Squelch opens when [MONI] is held
down
and
received.
2
OFF
Disable
2
CO
Carrier operated scan (resume)
2
TO
Time operated scan (resume)
3
OFF
No priority setting
3
1
Set priority channel
4
1
Priority
(Only
priority " is enabled)
4
16
5
0.5
The period that radio checks a priority
channel from a normal channel when
5
5.0
there is no activity on priority channel.
6
0.5
Time until scan resumes when it is
stopped by signal input (Only valid in
6
5.0
time-operated scan).
7
0.1
Time until scan resumes when there is
no signal after it is stopped by signal
7
5.0
input.
8
0.1
Time until scan resumes after transmit
stops without compatible channel
8
5.0
associated signaling; Scan resume
time is decided by dropout delay
time/RX
carrier-operated/time-operated
mode
if
associated signaling appears.
9
0
It's the current channel during scan.
9
1
It's the channel where scan resumes
during scan; it's the channel where
scan is stopped during scan.
9
Remarks
compatible
signal
is
valid
when
"fixed
dwell
time
and
scan
compatible
channel

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tc-365

Table of Contents