PANEL
SIDE
TIP:
The connectors
to the Y-SUS
board are very
easy to
misalign and
plugged in.
The Connector
will be below
the actual pins
on the Y-SUS.
Look carefully.
See Tip section
page 133-134.
Y
-
Drive Lower Layout
Y
-
Drive Lower Layout
Y-SUS
SIDE
FG5V Volts from the
Y-SUS board and Logic
Signals from the Control
through the Y-SUS
board are supplied to
the Lower Y-Drive
Board on connector
P205.
Y-Drive signal (VSC)
from the Y-SUS board is
supplied to the Lower
Y-Drive Board on
connector P205 pins 11
and 12. Then the Lower
Y-Drive delivers the
V-Scan signal to the
upper via P209 to P108.