Set Up and Set Down Adjustments
Set Up and Set Down Adjustments
Observe the Picture while making these adjustments. Normally, they do not have to be done.
Y-Drive Test Point
All other DC Voltage adjustments should have already been made.
ADJUSTMENT LOCATIONS:
Top Left and Center Right
50
Set must be in "WHITE WASH"
SET-UP ADJUST:
1) Adjust VR601 and set the (A) portion of the
signal to match the waveform above. (150V ± 5V)
SET-DN ADJUST:
2) Adjust VR401 and set the (B) time of the
signal to match the waveform above. (100uSec 5uSec)