Connector P813 Identification, Voltages and Diode Check
Connector P813 Identification, Voltages and Diode Check
P813 CONNECTOR "SMPS" to "Main" P1006
Pin
Label
a
1
17V
3
Gnd
b
5
12V
7
Gnd
b
9
5V
b
11
5V
13
Gnd
15
Gnd
17
5V Det
19
RL On
21
M5 ON
23
Stby 5V
a
Note: The 17V turns on when the
VS On command arrives.
b
Note: The 5V/12V turns on when the
RL On command arrives.
Diode Mode Readings taken with all connectors Disconnected. DVM in Diode Mode.
STBY
Run
Diode Mode
0V
17.3V
Gnd
Gnd
0V
12V
Gnd
Gnd
5V
5V
5V
5V
Gnd
Gnd
Gnd
Gnd
.15V
5V
0V
3.73V
0V
3.24V
5V
5V
Pin
2
2.2V
Gnd
4
Open
6
8
Gnd
10
1.1V
12
Stby 5V
1.1V
Gnd
14
Gnd
16
18
AC Det
Open
20
VS On
Open
22
Open
Auto Gnd
c
24
Key On
Open
c
Note: If the Key On line is 4.39V, the
Main Power Switch is open.
Stand-By 5V will shut off.
41
Label
STBY
Run
a
17V
0V
17.3V
Gnd
Gnd
Gnd
b
12V
0V
12V
Gnd
Gnd
Gnd
b
5V
5V
5V
Gnd
Gnd
Gnd
Gnd
Gnd
Gnd
5V
0V
3.2V
Gnd
Gnd
0V
November 2009 50PQ30 Plasma
Diode Mode
2.2V
Gnd
Open
Gnd
5V
1.1V
5V
1.13V
Gnd
Not Used
5V
Open
Open
Open
0V
Open