Advertisement

Set Down Adjustment Too High or Low
Set Down Adjustment Too High or Low
Set Dn swing is Minimum 73uS Max 166uS+
(SET DN) Too High 166uSec
Full Clock Wise
(SET DN) Too Low
Counter Clock Wise
Panel Waveform Adjustment
NOTE: If Set DN too high, this set
If this happens, remove the LVDS
from Control board and make
100V off
necessary adjustments. Then
the Floor
reconnect LVDS select White Wash
Floor
All of the center washes out due to increased SET_DN time.
The center begins to wash out and arc due to decreased
SET DN time.
52
may go excessive bright,
then shutdown.
and adjust correctly.
November 2009 50PQ30 Plasma