Error History Log

This projector provides the error history log function. To check the logs, you need to enter the service mode and select
Group No. "91" and Item No. "0" to "49". The error code is displayed on the Data column. The description of the error
code is listed on the table below.
How to enter the service mode and selection of the group and item, see "Service Adjustment Menu Operation" on
page 23.
Group No. Item No.
91
0
1
2
3
.
.
.
48
49
Error
Normal
Power Failure
Temperature Error
Lamp Error
Data (Error Code)
(See table below)
<- Latest Error
Error Code
0
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
2000
2001
2100
2101
2102
2200
2201
2202
3000
3001
3002
Error Infomation
(See Powe Failure Detection Tree)
-
AV -5V
AV S5V
PJNET S5V
ANALOG 6V
ANALOG 3.3V
( MAIN 3.3V )
MAIN S-5V
( MAIN 6V )
FAN
M/A
ANALOG 1.8V
FPGA 1.5V
GAMMA 1.8V
GAMMA 15.5V
GAMMA 5V
GAMMA 12V
Sensor A detects abnormal temperature.
Sensor A fails measurement.
Sensor B detects abnormal temperature.
Sensor B fails measurement.
Sensors B-A temperature error.
Sensor C detects abnormal temperature.
Sensor C fails measurement.
Sensors C-A temperature error.
Lamp1 fails on
Lamp1 goes out
Communication Error on Lamp1
-57-