Electrical Adjustments

Service Adjustment Data Table

No. Item
Group
0
Thermal Monitor Read only
0 LM76(Temp) A Monitor
1 LM76(Temp) B Monitor
2 LM76(Temp) C Monitor
1
Atmosphere Monitor Read only
0 MPXA4114A(Pressure) Monitor
1 MPXA4114A(Pressure) Monitor
2 MPXA4114A(Pressure) Monitor
5
FAN A Monitor (PBS)
FAN B Monitor (Lamp-IN)
FAN C Monitor (Lamp-Front)
FAN D Monitor (Power)
FAN E Monitor (Panel)
FAN F Monitor (Exhust)
10
RS232C Setting
0 Reset Disable
11
PJ-Net Setting
0 LAN Card Switch
20
Logo prohibition
0 Logo prohibition
30
Color Shading/Gamma
0 Color Shading Correction On/Off
1 Gamma Correction On/Off
40
Dimmer Control
0 Dimmer Level
2 DIMMER CTRL LEVEL1
3 DIMMER CTRL LEVEL2
4 DIMMER CTRL LEVEL3
5 DIMMER CTRL LEVEL4
6 DIMMER CTRL LEVEL5
7 DIMMER CTRL LEVEL6
8 DIMMER CTRL LEVEL7
9 DIMMER CTRL LEVEL8
10 DIMMER CTRL LEVEL9
11 DIMMER CTRL LEVEL10
12 DIMMER CTRL LEVEL11
13 DIMMER CTRL LEVEL12
14 DIMMER CTRL LEVEL13
15 DIMMER CTRL LEVEL14
16 DIMMER CTRL LEVEL15
17 DIMMER AVE POINT
50
Auto-Picture Control
0 Auto-Picture Control Forced OFF
70
COOLING
0 COOLING_TIME
1 Not used
80
Projector Use time
0 PJ Time Reset
Function
Sensor A for External IC1691
Sensor B for Lamp IC1816
Sensor C for Panel IC1814
Atmosphere sensor
Atmosphere sensor [unit: mmHg]
Atmosphere sensor [unit:hpa]
Current voltage of Fan (0.01V unit)
Current voltage of Fan (0.01V unit)
Current voltage of Fan (0.01V unit)
Current voltage of Fan (0.01V unit)
Current voltage of Fan (0.01V unit)
Current voltage of Fan (0.01V unit)
* Do not change setting when using LAN card
PJ-Net Reset (0:Enable / 1:Disable)
LAN (0: Disable / 1: Enable)
Logo prohibition(0: Menu / 1: Forced)
Color Shading Correction (0:Off / 1:On)
Gamma Correction (0:Off / 1:On)
0:250 ~ 15:300W Effect only 300W
Bright level1 data: Bright level1 when less than the value
Bright level2 data: Bright level2 when less than the value
Bright level3 data: Bright level3 when less than the value
Bright level4 data: Bright level4 when less than the value
Bright level5 data: Bright level5 when less than the value
Bright level6 data: Bright level6 when less than the value
Bright level7 data: Bright level7 when less than the value
Bright level8 data: Bright level8 when less than the value
Bright level9 data: Bright level9 when less than the value
Bright level10 data: Bright level10 when less than the value
Bright level11 data: Bright level11 when less than the value
Bright level12 data: Bright level12 when less than the value
Bright level13 data: Bright level13 when less than the value
Bright level14 data: Bright level14 when less than the value
Bright level15 data: Bright level15 when less than the value
Average point data for dimmer
0:follows to Menu, 1:Forced OFF
Cooling time period after power off
It resets the time when the value is changes to 10.
-28-
These initial values are the reference data written from the
CPU ROM to memory IC when replaced new memory IC. The
adjustment items indicated with "✻" are required to readjust fol-
lowing to the "Electrical adjustments". Other items should be
used with the initial data value.
Range
-
-
-
-
-
-
-
-
-
-
-
0 / 1
0 / 1
0 / 1
0 / 1
0 / 1
0 ~ 15
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
1~16
0 / 1
10-120
0 ~ 10
Initial Value
-
-
-
-
-
-
-
-
-
-
-
0
0
0
1
Not memorized
1
Not memorized
15
7
14
21
28
35
42
49
56
63
70
77
84
91
98
105
4
0
90
-1
0