Electrical Adjustments
Group
No. Item
90
Operation History
0 OPERATION_HISTORY_1
~
49 OPERATION_HISTORY_50
50 OPERATION_HISTORY Reset
91
Projector Failure History
0 Warning Log 1
~
49 Warning Log 50
50 Warning Log Reset
112
Lamp Config
0 Lamp Config Change
113
Lamp Reset Counter (Read only)
0 Lamp Reset Counter
115
Kamp Go Out
0 Lamp Go Out
116
Lamp Replace Display
0 Display when Lamp Replace time
120
RC KEY Disable
1 RC KEY Front/Rear Disable
130
75 ohm terminated
0 TERM_1
1 TERM_2
140
Fan Control
0 Fan A Max (DAC)
1 Fan A Min (DAC)
2 Fan B Max (DAC)
3 Fan B Min (DAC)
4 Fan C Max (DAC)
5 Fan C Min (DAC)
6 Fan D Max (DAC)
7 Fan D Min (DAC)
8 Fan E Max (DAC)
9 Fan E Min (DAC)
10 Fan F Max (DAC)
11 Fan F Min (DAC)
141
Fan Optiion
0 Hi-Land SW
1 Not used
142
Fan Temp Error Setting
0 Temp A Warning
1 Temp B Warning
2 Temp C Warning
3 Temp B-A Warning
4 Temp C-A Warning
143
Fan Manual Control for factory exam
144
Fan Table Settingl for factory exam
145
Fan Offset Setting for factory exam
146
Fan Start Setting for factory exam
147
Fan Air pressure Setting for factory exam
148
Fan Ceiling Setting for factory exam
Function
Operation history in last operation
Operation history last 50th operation
It resets the history when the value is changed to 10.
Latest Failure log
50th Failure log
It resets the Log when the value is changed to 10.
Lamp life selection (Step : 500h)
Reset times of the Lamp time counter
0: Disable / 1: Enable
0: Disable / 1: Enable
0:Enable / 1:Front RC Disable / 2:Rear RC Disable / 3:RC KEY All Disable
Input1(D SUB) terminated (0: OFF / 1: ON)
Input2(BNC) terminated (0: OFF / 1: ON)
0:Normal Mode1: High-land Mode (Fan max speed continuously)
Not used
Read only
Temp A to judge the temp error (x10)
Temp B to judge the temp error (x10)
Temp C to judge the temp error (x10)
Temp B-A to judge the temp error (x10)
Temp C-A to judge the temp error (x10)
-29-
Range
Initial Value
0~32767
0
0~32767
0
0 ~ 10
0
* See "Power Falure Error His-
tory"
0 ~ 32767
0
0 ~ 32767
0
0 ~ 10
0
1000 ~8000
2000/1500
0 ~127
0
0 / 1
0
0 / 1
0
0 ~ 3
0
0 / 1
0
0 / 1
0
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 255
0 ~ 1
0
--
300W
0 ~ 1000
460
0 ~ 1000
800
300 ~ 1000
590
0 ~ 1000
500
0 ~ 1000
270