Diagnosis Of Power Failure With Rs-232C Port; Diagnosis Procedure - Sanyo PLV-80 Service Manual

Multimedia projector
Hide thumbs Also See for PLV-80:
Table of Contents

Advertisement

Chassis Description

Diagnosis of Power Failure with RS-232C port

This projector provides a function to get the error information of the projector by using the RS-232C serial port for the
power failure diagnosis.
The further error information of the power failure and fan failure can be found out by using this function.

Diagnosis procedure

1
Connect a RS-232C serial cross cable to SERIAL PORT IN on the projector and serial port on the PC.
2
Launch a communication software "Hyper terminal" provided with PC and setup the communication condition as
follows;
Baud rate
Parity check
Stop bit
Flow control
Data bit
3
Turn on the projector. Check that the LED shows a power
failure. (All the LEDs except LAMP LED are blinking)
4
Type a diagnosis command of the power failure "CR
ALLPFAIL" and press a "ENTER" key within 1 second on
the command window of the software.
The error information will be listed on the window as the
right.
Check the status column. If "NG" is listed, the power
failure occurs on its signal line(Power Line Name). In
case of the right table, this error information means that
the power failure occurs on the 6V power supply on the
ANALOG circuit on the main board. Check if the parts
connected to 6V power supply line are defective.
Also the error information may be listed multiple as the
below;
In the above case, 2 kinds of causes are considered.
One is the power failure occurs on the multiple places
at the same time, other is a power failure affects mul-
tiple power supply lines even if the failure occurs on the
single place.
In the first case, Check if the parts connected to the mul-
tiple power supply lines are defective. In the later case,
determine a failure point referring to the power supply
flow chart on next page. Basically, if the power failure oc-
curs on the upper side of power supply, the power failure
is also detected on lower side of power supply frequently. If the failure occurs on the lower side of power supply,
it is lightly affected to the upper side of the power supply. In the above case, because the failure occurs on the 6V
power supply on the ANALIG circuit on the main board, the failure is also detected on the 3.3V power supply on the
ANALOG circuit on the main board.
* See "Power Failure Detection Tree" for further description of the Error Information.
: 19200 bps
: none
: 1
: none
: 8
CR ALLPFAIL
000 AV,
000 AV,
000 PJNET,
000 ANALOG,
000 ANALOG,
000 MAIN,
000 FAN,
........ ...............
CR ALLPFAIL
000 AV,
000 AV,
000 PJNET,
000 ANALOG,
000 ANALOG,
000 MAIN,
000 FAN,
........ ................
-58-
Error Information
(Signal Name)
-5V
OK
S5V
OK
S5V
OK
6V
NG
3.3V
OK
S-5V
OK
16V
OK
.........
......
-5V
OK
S5V
OK
S5V
OK
6V
NG
3.3V
NG
S-5V
OK
16V
OK
.........
......
Status
Error
Error

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plv-80l

Table of Contents