Sanyo PLV-80 Service Manual page 39

Multimedia projector
Hide thumbs Also See for PLV-80:
Table of Contents

Advertisement

Electrical Adjustments
Group
No. Item
7 (Not used)
8 VSBEG
454
RGB-Video (1080P-50)
0 Total Dots
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
5 (Not used)
6 (Not used)
7 (Not used)
8 VSBEG
455
RGB-Video (1080P-50)
0 Total Dots
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
5 (Not used)
6 (Not used)
7 (Not used)
8 VSBEG
600
PW Option
0 FrameLock Option
1 AV Screen Force Trie Mode
2 Field Sens Invert Enable
3
4 Sub Image Enable
6 Divide Refresh Disable
620
Sub Brightnes
0 Center Contrast
1 Center Brightness
2 Center Color
3 Center Tint
4 Center Sharpness
5 Alpha Contrast
6 Alpha Brightness
7 Alpha Color
8 Alpha Tint
9 Alpha Sharpness
680
Auto Caribaration
0 Execute Calibration
1 Loop Count
2 OFFSET AREA H START
3 OFFSET AREA V START
4 GAIN AREA H START
5 GAIN AREA V START
6 Image AREA H WIDTH
7 Image AREA V HIGHT
8 OFFSET target
9 OFFSET torelance
Function
(Not used)
* Read only
(Not used)
(Not used)
(Not used)
* Read only
(Not used)
(Not used)
(Not used)
0: Frame Lock OFF at PC signal
1: Frame Lock ON at PC signal and 47Hz~Panle freq.
Changes Natural Wide -> True at AV signal
0: Disable
1: Enable
Switch "FLDINV" Setting
0: Disable
1: Enable
0: Disable (Disable Service 620)
1: Enable (Enable Service 520)
0: Enable (Normal)
1: Disable Not Memorized
Composite / S-Video / Component /
Digital /D-RGB-Video/AnalogRGB /
RGB-Video / HDCP-PC /HDCP-AV /
SCART
Value = (Menu Value - MENU avarage ) x Alpha / 10 + Center
(Setting value to PW)
Contrast
[Max] 1023 [Min] 0
Brightness [Max] 1023 [Min] 0
Color
[Max] 1023 [Min] 0
Tint
[Max] 180 [Min] 0
Sharpness [Max] 23 [Min] 0
Executes Auto Calibration when the value changes
(For 100% White Adj. PC)
Maximum Loop with OFFSET -> GAIN
H-Start Position with Black Level Acquisition Area
V-Start Position with Black Level Acquisition Area
H-Start Position with White Level Acquisition Area
V-Start Position with White Level Acquisition Area
Black/White Level Acquisition Area Width
Black/White Level Acquisition Area Height
Black Level adj. Target Value
Black Level Adj. Tolerance Range
-39-
Range
Initial Value
0 ~ 15
2
0 ~ 3000
1878
0 ~ 3000
1366
0 ~ 3000
159
0 ~ 3000
54
0 ~ 1500
1080
0 ~ 15
2
0 ~ 3000
1957
0 ~ 3000
1366
0 ~ 3000
159
0 ~ 3000
54
0 ~ 1500
1080
0 ~ 15
2
0 ~ 1
1
0 ~ 1
0
0 ~ 1
0
0 ~ 1
1
0 ~ 1
0
577/577/577/492/492/
0 ~ 1023
535/577/492/492/577
520/520/520/520/520/
0 ~ 1023
516/520/520/520/520
512/512/400/512/512
0 ~ 1023
/512/400/512/512/512
95/95/95/95/95
0 ~ 1023
/95/95/95/95/95
8/8/8/8/8
0 ~ 1023
/8/8/8/8/8
120/120/120/120/120/
0 ~ 1023
120/120/120/120/120
120/120/120/120/120/
0 ~ 1023
120/120/120/120/120
120/120/120/120/120/
0 ~ 1023
120/120/120/120/120
10/10/10/10/10
0 ~ 1023
/10/10/10/10/10
10/10/10/10/10
0 ~ 1023
/10/10/10/10/10
0 ~ 1
0
1 ~ 30
3
0 ~ 1000
25
0 ~ 1000
500
0 ~ 1000
975
0 ~ 1000
500
0 ~ 4095
13
0 ~ 4095
9
0 - 127
1
1 - 127
1