Special installation (When the display is put in a box)

3.5.4 When the display is put in a box

Operating this display in confined spaces is not recommended.
• If the display is to be used in a confined space, observe the following conditions shown in the drawing below:
A ≥ 50
B ≥ 50
C ≥ 10
D ≥ 50
Use a mesh with aperture efficiency of 50 % or more.
If hot air remains in the enclosed space, the temperature may rise causing a malfunction or fire. As a precaution, the
inner wall should have sufficient heat resistance or fire resistance.
✩ Usage temperature conditions (BOX air temperature)
• Ambient temperature: 0 °C to 35 °C
: Thermometer
(temperature measurement point)
Exhaust side
A
Rear view (the following area should be made of mesh)
50 mm
50 mm
42
A+
800 mm or more
A+
800 mm or more
Outside air temperature
measuring point
10 mm
Intake side
A
A+
50 mm
A+
50 mm
[507CMX]
A ≥ 50
B ≥ 50
C ≥ 10
D ≥ 50
C
D
Mesh with aperture efficiency
of 50 % or more
10 mm