Programming Console Function

6-12 Programming Console Function

6-12-1 Usable Systems

• If data does not reach the printer within 60 seconds after sending starts, the
message 'Finished Printer output failed' is displayed.
After confirming the result of the check, press Quit. The NT31/NT31C returns to
the I/F CHECK MENU screen.
The NT31/NT31C has been equipped with the Programming Console function,
which allows it to be used like a C200H-PRO27-E Programming Console for
CPM1, CPM2A, CPM2C, CQM1, CQM1H, C200HX/HG/HE (-Z)E, CS-series
CS1G/CS1H, or SRM1 PLCs.
Except for recording (saving) ladder programs on cassette tape and replaying
(reading) them, almost all the functions of a Programming Console can be
executed.
Note When the programmable controller functions are used, carefully check that the
system is safe before carrying out the following operations.
• Changing monitor data
• Switching the operating mode
• Forced set or reset
• Changing a present value or set value
The Programming Console function can communicate with the PLC with the
communication methods indicated in the following table.