Device Monitor Function

6-13-1 Compatible Systems

6-13-2 Connection Method

CQM1H or
C200HX/HG/HE(-ZE)
CQM1 or C200HS
CPM1, CPM2A, or SRM1
CPM2C
226
The following table shows the combinations of communications methods and
PLCs that can support the PT's Device Monitor function.
Communications
method
1:1 NT Link
C200HS-CPU21-E
C200HS-CPU23-E
C200HS-CPU31-E
C200HS-CPU33-E
C200HE-CPU32 (-Z)E
C200HE-CPU42 (-Z)E
C200HG-CPU33 (-Z)E
C200HG-CPU43 (-Z)E
C200HG-CPU53 (-Z)E
C200HG-CPU63 (-Z)E
C200HX-CPU34 (-Z)E
C200HX-CPU44 (-Z)E
C200HX-CPU54 (-Z)E
C200HX-CPU64 (-Z)E
C200HX-CPU65-ZE
C200HX-CPU85-ZE
1:N NT Link
C200HE-CPU32 (-Z)E
C200HE-CPU42 (-Z)E
C200HG-CPU33 (-Z)E
C200HG-CPU43 (-Z)E
C200HG-CPU53 (-Z)E
C200HG-CPU63 (-Z)E
C200HX-CPU34 (-Z)E
C200HX-CPU44 (-Z)E
C200HX-CPU54 (-Z)E
C200HX-CPU64 (-Z)E
C200HX-CPU65-ZE
C200HX-CPU85-ZE
*1: A CPM1-CIF01 RS-232C Adapter is required.
*2: Use a Conversion Cable (CPM2C-CN111 or CS1W-CN114/118), CPM1-CIF01
RS-232C Adapter, or CPM1-CIF11 RS-422A Adapter to connect to the PLC.
The 1:1 NT Link or 1:N NT Link can be used. The connection method is exactly
the same as for the 1:1 NT Link or 1:N NT Link. Refer to Section 4 Connecting to
the Host from the RS-232C Port or Section 5 Connecting to the Host from the
RS-422A/485 Port for details on connecting to the PLC.
The 1:1 NT Link can be used. The connection method is exactly the same as for
the 1:1 NT Link. Refer to Section 4 Connecting to the Host from the RS-232C
Port or Section 5 Connecting to the Host from the RS-422A/485 Port for details
on connecting to the PLC.
The 1:1 NT Link can be used in all CPUs and the 1:N NT Link can also be used in
-V2 and higher versions of the SRM1. The connection method is exactly the
same as for the 1:1 NT Link or 1:N NT Link. With a CPM1, connect the RS-232C
cable to the peripheral port via a CPM1-CIF01 RS-232C Adapter or
CPM1-CIF11 RS-422A Adapter.
Refer to Section 4 Connecting to the Host from the RS-232C Port or Section 5
Connecting to the Host from the RS-422A/485 Port for details on connecting to
the PLC.
The 1:1 NT Link can be used. The connection method is the same as for the NT
Link (1:1). Connect to the PLC's communications connector with a CPM2C-
Section
PLC model
*1
CPM1-10CDR-j
*1
CPM1-20CDR-j
*1
CPM1A-10CDj-j
*1
CPM1A-20CDj-j
*1
CPM1A-30CDj-j
*1
CPM1A-40CDj-j
CPM2A-30CDjj-j
CPM2A-40CDjj-j
CPM2A-60CDjj-j
CPM2C-10jjjjjj-j
CPM2C-20jjjjjj-j
CQM1-CPU4j-EV1
CQM1H-CPU21
CQM1H-CPU51
CQM1H-CPU61
SRM1-C02-V2
CQM1H-CPU21
CQM1H-CPU51
CQM1H-CPU61
SRM1-C02-V2
CS1G-CPU42-E(V1)
CS1G-CPU43-E(V1)
CS1G-CPU44-E(V1)
CS1G-CPU45-E(V1)
CS1H-CPU63-E(V1)
CS1H-CPU64-E(V1)
CS1H-CPU65-E(V1)
CS1H-CPU66-E(V1)
CS1H-CPU67-E(V1)
6-13
*2
*2